Products

  • GDJB-6000D Smart Substation Relay Protection Test System

    GDJB-6000D Smart Substation Relay Protection Test System

    GDJB-6000D Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to the technical specifications related to “DL/T 624-2010 Relay Protection Micro-type Test Device Technical Conditions”, and based on IEC61850 communication standard, realized by using advanced computer technology.

  • GDB-P Auto Transformer Turns Ratio Tester

    GDB-P Auto Transformer Turns Ratio Tester

    According to IEC and the relevant national standards, transformer turns ratio test is a necessary project in the process of power transformer production, user handover and maintenance test.

     

  • GDSL-BX-200 Primary Current Injection Test Set

    GDSL-BX-200 Primary Current Injection Test Set

    GDSL-BX-200 Primary Current Injection Test Set, is mainly used in calibration for current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc. 

  • GDWR-5A Earth Resistance Tester for Ground Grid

    GDWR-5A Earth Resistance Tester for Ground Grid

    GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy.

  • GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator is mainly used for the setting and verification of various electrical equipment. With features of reasonable design, convenient operation and large output power, it is widely used in electric test sites of power system, railway, petrochemical, metallurgy and mining enterprises.

  • VLF AC Hipot Test Set

    VLF AC Hipot Test Set

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. 

  • VLF AC Hipot Test Set 80kV

    VLF AC Hipot Test Set 80kV

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test.

  • GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.

     

     

     

  • GDFR-D1 AC/DC High Voltage Divider

    GDFR-D1 AC/DC High Voltage Divider

    GDFR-D1 Series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  

  • GDZJ-5S Surge Generator For Motor

    GDZJ-5S Surge Generator For Motor

    GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment.

  • GDZJ-30S Turn-to-Turn Surge Withstand Tester

    GDZJ-30S Turn-to-Turn Surge Withstand Tester

    GDZJ-30S is used to test turn-to-turn insulation strength of rate voltage 10kV motor, HV and LV motor, AC/DC motor, transformer winding and coil winding.

     

  • GDJF-2007 Digital Partial Discharge Analyzer

    GDJF-2007 Digital Partial Discharge Analyzer

    GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable.

     