Transformer Test Equipment

  • GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 is high-precision instrument for testing dielectric loss angle and volume resistivity of insulating oil or other insulating liquids. 

  • GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.

  • GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

    GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

    GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.

     

  • GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester

    GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester

    GD6100C Automatic Precision Oil Dielectric Loss Tester, is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. 

  • GD6100D  Insulation Oil Tan Delta Tester

    GD6100D Insulation Oil Tan Delta Tester

    In the preventive test of electrical equipment insulation, periodic measurement of insulating oil parameters of electrical equipment is required. The measurement of dielectric loss and resistivity of insulating oil is one of the most important items. For a long time, most of them have been measured by the bridge method, which is cumbersome to operate, and the measurement accuracy is affected by many factors, resulting in large measurement errors

     