Nā Ho'āʻo Kiʻekiʻe Voltage AC no GIS
●Mea hoʻololi
●Pūnaehana GIS
●SF6 mea hoʻololi
●Uea
●ʻO ke kuʻi ʻana
●mea hoʻopololei
●CT/PT
●ʻO nā mea hana capacitive ʻē aʻe
●Piʻi ka mahana liʻiliʻi ma ka haʻawe helu.ʻO nā ʻano reactors maloʻo a ʻaila paha, ikaika mechanical kiʻekiʻe, insulation maikaʻi, maikaʻi a hilinaʻi.
●Hiki ke hoʻololi i ke kumu hoʻomalu alapine.Paʻa ikaika, kūpaʻa maikaʻi.Me nā ʻano hana he nui, maʻalahi e hana.
●Me ka 220V a i ʻole 380V ka mana hoʻokahi, kūpono no ka ʻike mana ma ka pūnaewele.
●Hoʻonohonoho maʻalahi.ʻOkoʻa ʻano reactors no ke koho, hoʻokō i nā koi mea hoʻāʻo like ʻole.Multifunctional, pono ke kumu kūʻai.
●Hoʻohālikelike ʻia ka volta puka: ma muli o nā mea hoʻāʻo like ʻole.
●ʻO ke alapine puka: 20-300Hz.
●Ka nalu: ka nalu maʻemaʻe, THD <1.0%.
●Max.kaha: 1000kVA a ma lalo.
●Hana Hana: Hoʻomau ka manawa hana 15mins hoʻokahi manawa ma ka mana piha piha.(a i ʻole ka makemake o ka mea kūʻai aku.)
●ʻO ka hoʻoponopono pinepine ʻana: 0.1Hz, paʻa ʻole <0.05%.
●Ka Mana Mana: 380 / 220V ± 15% / 50Hz ± 5%.
GDTF-108/108 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-108 |
Kaha (kVA) | 108 |
Laulā noi | 31500kVA a i ʻole ma lalo |
35kV mea hoʻololi mana | |
35kV kaapuni kaapuni a me ka bus bar, insulators | |
10kV (300 mm²) uwea 2000m | |
Uea 35k V (300 mm²) 500m | |
Nā hoʻonohonoho nui | 5kW kumu alapine ʻokoʻa 1 set |
5kVA Mea hoʻololi hoihoi 1 set | |
Nā Reactors 27kV/1A 4sets | |
capacitive divider 100kV | |
GDTF-216/216 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-216 |
Kaha (kVA) | 216 |
Laulā noi | 110kV Kaapuni kaapuni a me ka pahu kaʻa |
110kV GIS | |
35kV(300 mm²) uwea 1500m | |
10kV(300 mm²) uwea 3km | |
110kV ka mea hoʻololi insulation piha | |
Nā hoʻonohonoho nui | 10kW Puna alapine hoʻololi 1 set |
10kVA Mea hoʻololi hoihoi 1 set | |
Nā Reactors 54kV/1A 4sets | |
capacitive mahele 200kV | |
GDTF-270/270 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-270 |
Kaha (kVA) | 270 |
Laulā noi | 110kV GIS a me ka transformer |
110kV GIS a me ka transformer | |
35kV (300 mm²) uwea 2km | |
Nā hoʻonohonoho nui | 15kW Puna alapine ʻokoʻa 1 set |
15kVA Mea hoʻololi hoihoi 1 set | |
Nā Reactors 54kV/1A 5sets | |
capacitive divider 300kV | |
GDTF-400/400 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-400 |
Kaha (kVA) | 400 |
Laulā noi | 220kV GIS a me ka transformer |
10kV (300 mm²) uwea 4km | |
35kV (300 mm²) uwea 1km | |
Nā hoʻonohonoho nui | 20kW Puna alapine ʻokoʻa 1 set |
20kVA Mea hoʻololi hoihoi 1 set | |
Reactor | |
capacitive divider 400kV | |
GDTF-520/260 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-260 |
Kaha (kVA) | 520 |
Laulā noi | 110KV Kaapuni kaapuni a me ka pahu kaʻa |
110kV GIS | |
110kV (300 mm²) uwea 800m | |
35kv (300 mm²) uwea 3km | |
10kV (300 mm²) uwea 6km | |
110kv ka mea hoʻololi insulation piha | |
Nā hoʻonohonoho nui | 25kW Puna alapine hoʻololi 1 set |
25kVA Mea hoʻololi hoihoi 1 set | |
Reactor 65kV/2A 4sets | |
capacitive divider 300kV | |
GDTF-500/500 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-500 |
Kaha (kVA) | 500 |
Laulā noi | 220kV a i ʻole ma lalo o CT/PT |
220kV a i ʻole ma lalo o ka busing | |
220kV a i ʻole nā Insulators, nā mea hoʻokaʻawale | |
220kV a i ʻole ma lalo o ka mea hoʻopau kaapuni | |
220kV a i ʻole ma lalo o ka mea hana hoʻokaʻawale | |
Nā hoʻonohonoho nui | 20kW Puna alapine ʻokoʻa 1 set |
20kVA Mea hoʻololi hoihoi 1 set | |
Reactor 125kV/1A 4sets | |
capacitive divider 500kV | |
GDTF-600/600 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-600 |
Kaha (kVA) | 600 |
Laulā noi | 110kV (300 mm²) uwea 800m |
35kv (300 mm²) uwea 110m | |
35-220kV GIS, transformers, insulators | |
Nā hoʻonohonoho nui | 30kW Puna alapine hoʻololi 1 set |
30kVA Mea hoʻololi hoihoi 1 set | |
Reactor 120kV/1A 5sets | |
capacitive divider 600kV | |
GDTF-800/800 | |
Voli uila komo (V) | 380 |
Puke uila puka (kV) | 0-800 |
Kaha (kVA) | 800 |
Laulā noi | 110kV (300 mm²) uwea 800m |
220kv (300 mm²) uwea 500m | |
35-500kV GIS, transformers, insulators | |
Nā hoʻonohonoho nui | 40kW Puna alapine hoʻololi 1 set |
40kVA Mea hoʻololi hoihoi 1 set | |
Reactor 200kV/1A 4sets | |
capacitive mahele 800kV |