Mea Ho'āʻo Voltage Kiʻekiʻe
Hana ʻo HV HIPOT i nā ʻano mea hana hoʻokolohua kiʻekiʻe.
ʻO mākou kahi mea hoʻolako hoʻonā hoʻokahi no nā huahana hoʻokolohua kiʻekiʻe-voltage e pili ana i kāu koi.


1. ʻO GDYD moʻo AC/DC Hipot Test Set
ʻO ka hoʻāʻo pinepine ʻana o ka mana ke ala kūpono a pololei e hoʻāʻo ai i ka ikaika insulation no nā mea uila, mea hana, a me nā mīkini.Nānā ia i nā hemahema pōʻino e hōʻoiaʻiʻo ana i ka hana mau ʻana o nā lako uila.
ʻO AC/DC Hipot Test Set, i kapa ʻia ʻo AC/DC dielectric test tool, hiki ke hoʻāʻo i nā ʻano mea hoʻāʻo he nui, me:
• Kaapuni kaapuni
• Nā mea hoʻololi
• Hoʻopaʻa hou
• Uea
• Nā kāpana
• CT/PT
• Nā kahua mokulele mokulele
• Nā pōhaku lepo lāʻau wela
• ʻO nā ʻōmole hamo
• Nā mīkina lima lima a me nā kāmaʻa
• Nā pākeʻe insulation, nā kaula
• Nui nā ukana MV a me HV
Loaʻa nā hiʻohiʻona maʻamau mai 10kV-300kV AC.
ʻEkolu ʻano o ka ʻāpana mana no ke koho ʻana,
• GDYD-M series Pointer hōʻike mana
• GDYD-D moʻo Kikohoʻe hōʻike mana
• GDYD-A series Automatic PLC controller


2. AC Pūnaehana ho'āʻo Resonant
Hoʻohana ʻia ka hoʻāʻo resonant AC i ke ala resonance e pale ai i ka hoʻāʻo ʻana o ka volta.Hoʻolālā kūikawā ia no nā mea mana nui a me nā mea uila kiʻekiʻe, me:
• Nā uwea mana
• Nā mea hoʻololi mana
• Ka mana ahi a me ka wai uila
• GIS
• Kaʻa pahi
• CVT
No nā mea ho'āʻo capacitive e like me ke kaula mana, GIS, nā mea hoʻololi a me nā mea ʻē aʻe, hoʻohana maʻamau mākou i ke ʻano hoʻāʻo alapine ʻokoʻa, GDTF series AC Resonant Test System.
No nā mea hoʻāʻo inductive e like me nā kaʻa, nā mea hana, CVT a me nā mea ʻē aʻe, hoʻohana maʻamau mākou i ke ʻano hōʻike hoʻoponopono inductance, GDTL series AC Resonant Test System.


3. GDYT series Partal Discharge Test System
ʻO kekahi mau hiʻohiʻona he corona manuahi, hoʻolālā ʻia e lilo i kumu AC no ka hoʻokuʻu hapa a me ka hoʻāʻo ʻana i ka power factor/tan delta.Hiki ke hoʻolālā ʻia ka ʻōnaehana ma muli o nā mea hoʻāʻo like ʻole, me ka hoʻohana ʻana i ke ala alapine mana a i ʻole ke ʻano hoʻāʻo resonant.


4. GIT series SF6 Gas Insulated Mobile High Voltage Partal Discharge Test System
Hoʻolālā kūikawā ia no ka High voltage GIS, GIS transformers.
Hiki iā ia ke ho'āʻo ma lalo nei:
• ʻO ke alapine mana a i ʻole ke alapine hoʻololi ke kū i ka hoʻāʻo ʻana i ka volta
• ho'āʻo hoʻokuʻu hapa
• ka ho'āʻo pololei o ka mea hoʻololi GIS
Pono:
• Hoʻopaʻa maikaʻi ʻia ka volta kiʻekiʻe a pale ʻia i loko o nā pahu, pale i ka palekana o ke kanaka, ʻaʻohe pilikia o waho.
• Ana hoao pololei.
• ʻO keʻano palekana loa o ka ho'āʻo voltage kiʻekiʻe.
• Inā hana ʻia ka HV bushing type, hāʻawi ʻia ka mea hydraulic no ka maʻalahi o ka hāpai ʻana.
• Pūnaehana ʻole corona ʻoiaʻiʻo.


5. VLF AC Hipot hoao
ʻOi aku ka maikaʻi o ka hoʻohana ʻana i ka VLF AC Hipot Test Set no ke kaula me ka hoʻāʻo ʻana i ka volta.
6. GDZG moʻo DC Hipot hoʻāʻo hoʻonohonoho
Hoʻohana ʻia ka pūʻulu GDZG o DC Hipot Test Set no ka hoʻāʻo ʻana i ka DC kiʻekiʻe no nā mea hopu zinc oxide, nā mea hopu puʻu magnetic, nā kaula mana, nā mea hana, nā mea hoʻololi, nā mea hoʻokaʻawale a me nā mea hana ʻē aʻe.ʻO 30-500kV ka uila i helu ʻia.


7. GDFR moʻo High Voltage Divider
Hiki i ka HV HIPOT ke hāʻawi i ka mea hoʻokaʻawale uila kiʻekiʻe.Hoʻopaʻa ʻia nā kumu hoʻohālike a pau e ka hale hana HV aupuni.
GDFR-C1 AC/DC mea hoʻokaʻawale uila kiʻekiʻe
GDFR-C2 AC mea hoʻokaʻawale uila kiʻekiʻe
GDFR-C3 DC mea hoʻokaʻawale uila kiʻekiʻe
GDFR-C4 VLF mea hoʻokaʻawale uila kiʻekiʻe
ʻO GDFR-C5 ka mea hoʻokaʻawale uila