ʻO ka wehewehe ʻana o Capacitance & Tan Delta Tester
ʻO ka capacitance & tan delta tester kahi ala maʻamau i ka hoʻāʻo ʻana i ka insulation, hiki iā ia ke nānā pono i ka hoʻohaʻahaʻa ʻana o ka wai o nā lako uila, a me nā hemahema kūloko.ʻO ke alapine ʻokoʻa ka capacitance a me ka tan delta tester kahi mea hana hoʻāʻo kiʻekiʻe i hoʻomohala kūʻokoʻa e HV Hipot.Hoʻohana nui ʻia ia no ke ana ʻana o ka capacitance & tan delta tangent a me ka capacitance o nā mea mana kiʻekiʻe-voltage i nā mea kanu mana, substations a me nā māla ʻē aʻe a i ʻole nā laboratories.Hiki ke ʻike maikaʻi ʻia ka capacitance ʻokoʻa a me ka tan delta tester i ka pau ʻana o ka wai a me nā hemahema kūloko o ka insulation lako uila.Hoʻohana nui ia i ka capacitance & tan delta ana o nā transformers, transformers, nā kaula uila a me nā mea hana ʻē aʻe i ka ʻoihana mana.
GD6800 capacitance & tan delta mea hōʻike
Hoʻohana i ka capacitance & tan delta tester
Hoʻohana nui ʻia ka capacitance & tan delta i ka hana uila, ka hoʻokomo ʻana i nā lako uila, ka hāʻawi ʻana a me ka hoʻāʻo pale.He kūpono hoʻi ka mea hana no ke ana ʻana i ka tgδ a me ka capacitance o nā lako uila uila kiʻekiʻe ma nā hale hana, nā hale hana a me nā ʻāpana noiʻi ʻepekema;hiki ke hoʻohana ʻia e hoʻāʻo i ka capacitance & tan delta o ka ʻaila insulating ke hoʻolako ʻia me nā kīʻaha aila insulating.
Nā hiʻohiʻona o ka capacitance & tan delta tester
ʻO ka mea hana he hale hoʻohui me ka capacitor maʻamau i kūkulu ʻia a hoʻonui i ka mana, ka liʻiliʻi, ke kaumaha māmā, maʻalahi ke lawe, ka hana maʻalahi, ke ana ʻana, ka heluhelu intuitive, ʻaʻohe hoʻololi, precision kiʻekiʻe, a me ka ikaika anti-interference.
ʻO ke ʻano o ka capacitance & tan delta tester
Hoʻolako ʻia ka mea hana me kahi transformer step-up kiʻekiʻe, a ua lawe i nā hana palekana e like me ka pani ʻana i ka zero-crossing a me ka pale uila.I ka wā o ka hoʻāʻo, hoʻohui pololei i ka mana 220V AC, hiki ke hoʻopuka i 2KV, 5KV, 10KV mau pae like ʻole o ka volta kiʻekiʻe, maʻalahi ka hana a palekana.
ʻO ka hana o ka capacitance & tan delta tester
ʻO kēia mea hana he mea hana kiʻekiʻe no ke ana ʻakomi o ka capacitance & tan delta o nā lako mana kiʻekiʻe-voltage i nā mea kanu mana, substations a me nā māla ʻē aʻe, a hiki ke hōʻoia i ke ana pololei ʻana ma lalo o ke keakea ikaika o ke kahua uila.Ua hoʻohui ka mea hana i ka hana menu Kina, ʻoi aku ka maʻalahi o ka hana a ʻoi aku ka maʻalahi.Hoʻokahi hana, hoʻopau aunoa ka microcomputer i ke kaʻina hana holoʻokoʻa.ʻO ia ka capacitance kūpono & tan delta ana lako.
Ana ʻana o ka capacitance & tan delta tester
Hiki ke ana ʻia nā mea uila uila kiʻekiʻe ʻaʻole i hoʻopaʻa ʻia a i ʻole i hoʻopaʻa ʻia e nā ala wili mua a hoʻohuli.