ʻO GD-7018A ʻIkepili Fiber Optical
ʻO ka GD-7018 series optical fiber pipeline identifier hiki ke ʻimi pono a ana i ka hohonu o nā pipelines lalo, nā kaula a me nā kaula optical ma lalo o ke ʻano o ka ʻeli ʻole ʻana, a ʻike pono i nā wahi pōʻino o ka uhi waho o nā pipeline lalo a me kahi o ka. nā wahi hewa uwea lalo.Hoʻokomo ʻia ka mea hana i nā ʻenehana holomua loa e like me ka kānana ultra-narrow band, ke kamaʻilio uea Bluetooth, ke kūlana GPS, ka palapala ʻikepili maʻalahi e ka polokalamu loiloi ʻikepili ʻoihana a me ka hana maʻalahi o nā hōʻike hōʻike.ʻO ka ʻike a me ka nānā ʻana i nā ʻano pipeline metala, ka hoʻokele a me ka mālama ʻana i ka pipeline, ka hoʻolālā ʻana a me ke kūkulu ʻana o ke kūlanakauhale, ka nānā ʻana i ka pipeline i ka mana a me nā keʻena ʻē aʻe kekahi o nā mea pono no nā ʻāpana mālama pipeline.
(1) Nā hana he nui
1. Ka hana transmitter: Loaʻa iā ia ʻekolu mau ʻano noi hōʻailona o ke ʻano induction, ke ala pololei a me ke ʻano clamp, kūpono no nā manawa like ʻole.
2. Hoʻohana ʻia no ke ana ʻana i ka wahi, ke kuhikuhi, ka hohonu o ke kanu ʻana a me ke au i loko o nā paipu lalo a me nā kaula.
3. Hōʻike nā pua hoʻonohonoho hema a me ka ʻākau i kahi o ka pipeline i kuhi ʻia, a wikiwiki a pololei ka locationg;ʻo nā pua mua a me hope a me ka waiwai dB e hōʻike i ka wahi a me ka nui o ka wahi pōʻino o ka papa anticorrosive.
4. Me ka hana backlight, kūpono no ka hoʻopakele pilikia i ka pō.
5. ʻO ka hana hoʻonohonoho ʻāina ʻo GPS, ka palapala ʻāina pipeline maʻalahi.
6. 'Oihana kālailai 'ikepili lako polokalamu, 'akomi hanauna o ka hōʻike hōʻike.
7. ʻO nā hana kūikawā o ka mea hoʻokipa 7018E: Hoʻohana ʻia ia e ʻimi i nā hewa (ʻo ka hemahema o ka paipu e pili ana i ka pōʻino o ka papa anti-corrosion o waho, ʻo ka hemahema o ke kaula e pili ana i ka pōʻino o ka papa pale o waho), a no ka ʻike ʻana i ka pōʻino insulation. o na paipu malalo o ka honua.
8. Ke ana o kēia manawa: e ana i ke au i hoʻohana ʻia e ka transmitter i ka pipeline ma lalo o ka hoʻāʻo.
9. Hana multimeter: hiki iā ia ke ana i ka uila puka, ka laina laina, ka laina laina, ka impedance a me ka mana.E ho'āʻo i ka hoʻomau a me ka maikaʻi insulation o ke kaula ma mua a ma hope o ka huli ʻana i ka hewa.
10. Hoʻopili hoʻokomo waho: kūpono i kahi kahi i hiki ʻole ke hoʻopili pololei ʻia ka hōʻailona i ka wā e ʻike ai i ke kaula.
(2) Ke kūlana kūlana kiʻekiʻe
1. Hiki ke hōʻoia like ʻia nā ʻano ʻano ana like ʻole no ka hoʻonohonoho ʻana i ka pipeline (ke ʻano awāwa, ke ʻano kiʻekiʻe, ke ʻano ākea ākea, ke ʻano pua kiʻekiʻe) hiki ke hoʻopaʻa like ʻia e hōʻoia i ka pololei o ke kūlana pipeline.
2. ʻO ke ala kiʻekiʻe loa: hiki ke hoʻohana i ke ʻano peak, wide peak mode, peak arrow mode no ke ana ʻana i ka hoʻololi ʻana o ka ʻāpana ākea ((HX)) a i ʻole gradient ākea (△HX), a huli e like me ke kūlana o kona waiwai nui;
3. ʻO ke ala liʻiliʻi: E hoʻohana i ke ʻano o lalo e hoʻoholo i ke kūlana o ka waiwai liʻiliʻi ma ke ana ʻana i ka hoʻololi ʻana o ka ʻāpana kū pololei (HZ).
(3) Nui nā ʻano kani kani
1. Hiki ke koho ʻia nā ʻano hana ʻike like ʻole a hiki ke hōʻoia ʻia kekahi.
2. ʻO ke ʻano heluhelu pololei me nā ʻōwili pae ʻelua.
3. Single pae coil 80% ala, 50% ala.
4. 45 degere ke ano.
(4) Ke kū'ē kū'ē ikaika
1. He nui nā ʻāpana nānā: hiki ke ana ʻia nā ʻāpana ʻāpae (HX), ʻāpana kū pololei (HZ) a me ka gradient ākea (△HX).
2. Ka mana hoʻouna kiʻekiʻe: ʻO ka mana hoʻopuka o ka transmitter a hiki i 10W a hiki ke hoʻololi mau ʻia.Hiki ke koho arbitrarily e like me ka pono.
3. ʻOi aku ka nui o nā alapine hana:
Ka alapine o ka mea hoʻouna: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Ka alapine o ka mea loaa: lekiō, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. E like me nā hiʻohiʻona o ka pipeline target (mea, hale, hohonu kanu, lōʻihi, etc.), koho i ke alapine hana kūpono.
(5) Hana maʻalahi
1. Intuitive: Hoʻohana ʻia kahi hōʻike kiʻi no ka hoʻomau a me ka manawa maoli e hōʻike i nā ʻāpana like ʻole a me ka ikaika hōʻailona i ka wā o ke kaʻina ʻike.
2. 'Aunoa: E ho'ololi 'akomi i ke 'ano antenna pae 'elua a ho'ololi 'akomi i ka 'ike o ka mea ho'okipa ke ana i ka hohonu, i mea e loa'a ai ka hō'ailona ana maika'i loa, a e ho'i 'akomi i ke 'ano hana ma mua o ka pau 'ana.
(6) Hoʻomau manawa hana lōʻihi a me ka uku hoʻohana haʻahaʻa
Hoʻolakoʻia ka mea hoʻouna me kahi pahu pahu lithium nui, hiki ke hoʻokō i nā pono o ka mana o hoʻokahi lā mahina no kaʻikeʻana i ka mahinaʻai e ka uku hoʻokahi, a hiki ke hana houʻia, e hoʻemi nui ana i ke kumukūʻai o kaʻike.
(7) Transmitter --AC a me DC hoʻohana pālua
Ma lalo o nā kūlana maʻamau, inā piha ka pā uila, e hoʻohana i ka pūʻolo pila i kūkulu ʻia e hāʻawi i ka mana.Inā i ka wā o ka hoʻohana ʻana, haʻahaʻa ka pā uila, akā ʻaʻole i pau ka hana ʻike, hiki iā ʻoe ke hoʻopili pololei i kahi adapter mana i hoʻolaʻa ʻia, hiki ke hoʻohana maʻamau ka mea kani, me ka ʻole e kali i ka hoʻopiha piha ʻana o ka mea kani ma mua o ka hoʻohana ʻana.
ʻĀpana ʻenehana | Amoʻo | Bmoʻo | Cmoʻo | Dmoʻo | Emoʻo |
Huli 'ana i ka Frequency | 5 | 6 | 7 | 8 | 10 |
Ka pinepine | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
ʻO ke alapine ʻo Passive | 50Hz | 50Hz 100Hz | 50Hz 100Hz lekiō | 50Hz 100Hz lekiō | 50Hz 100Hz lekiō |
Kānana mana | × | × | √ | √ | √ |
Ka pinepine hewa | × | × | × | × | 2 |
Loaʻa hewa | × | × | × | × | √ |
ʻO ka pākaukau Lithium ion | √ | √ | √ | √ | √ |
He Papa | × | × | × | × | √ |
Ke ʻimi nei i ka hohonu(m) | 6 | 6 | 6 | 6 | 6 |
Waihona ʻikepili | × | × | × | √ | √ |