ʻO GDBT-8610P ka mea hōʻike impedance impedance
Hoʻohana nui ʻia ka GDBT-8610P Battery Tester i nā wahi aʻe:
●Telecom: Ke Keʻena kikowaena, nā kikowaena hoʻoili ʻikepili a me nā kahua mamao
●Nā Mea Hana Mana: Switchgear, Power Station and Power Plant
●Pūnaewele Waiwai: Pūnaehana ʻIkepili Hui
●Petrochemical: Nā ʻōnaehana hoʻomalu kaʻina hana
● Nā paepae waho
●Ke Aupuni: Kūloko a me ka ʻāina
● Nā Hale Hana ʻauhau a me ka loaʻa kālā
●Homeland Security, Kula, Koa a me ka Navy
●Nā ʻOihana Koa, Nā Keʻena Kinai Ahi a me nā Makai
● Pūnaehana UPS Halemai
● mea hoʻolako kaʻa uila
●Hana lako lako SLA
●Wide ho'āʻo laulā: 5 ~ 6000Ah, kūpono no hoʻokahi pūnaewele o 1.2V, 2V, 6V a me 12V
●Mea paʻa lima naʻauao a paʻa i ka lima, paʻa a maʻalahi ke hele
● Pākuʻi paʻi kala me nā hana koho o ka papa keyboard
● I ka manawa like e ho'āʻo ai no ka volta, ke kū'ē a me ka mana o nā pila
●Ke ana ma ka pūnaewele, ʻaʻole pono e wehe i ka pākaukau a me ke kaula mai kāna ʻōnaehana no ka hoʻāʻo ʻana, palekana a maʻalahi
●Ka hoʻāʻo wikiwiki no ka pākaukau a me ke kaula i kekona me ka hoʻāʻo ʻana i ka ʻikepili mālama auto
● ikaika anti-interference i ka manawa kiʻekiʻe me ka hana paʻa a pololei
●Ka ho'āʻo alapine haʻahaʻa ma mua o10 Hz, e pale pono i ke keakea mai ka capacitive kū'ē o ka pākaukau pono'ī
●Kūpili USB pololei no ka hoʻonui ʻana i ka polokalamu a me ka hoʻoili ʻana i ka ʻikepili i ka PC no ka nānā hou ʻana
●Powerful PC hoʻokele lako polokalamu, kūpono no ka mālama ʻana i ka ʻikepili a me ka nānā ʻana
●Ka hoʻomanaʻo nui no ka hoʻāʻo ʻana i ka mālama ʻikepili ma mua o 3000 pūnaewele
●Buzzer Alarm Function a me ka pale uila, palekana e hoʻohana
●Auto-calibration hana ma mua o ka hoʻāʻo ʻana, hoʻonui i ka hoʻāʻo pololei
●E ho'āʻo hou a me ka hana pānaʻi: hiki ke hoʻāʻo hou ʻia nā hana hewa a i ʻole nā hana me ka kaomi hoʻokahi
● ʻIkepili i hoʻopaʻa ʻia i loko o ka hoʻomanaʻo no ka hoʻohālikelike ʻana i kāu hoʻāʻo, a loaʻa nā waiwai kuhikuhi ponoʻī
Palena kūʻē | 0.00mΩ ~ 100mΩ | Laulā uila | 0.000V ~16V* |
Hoʻoholo hoʻokolohua min-ka uila -kūʻē
| 1mv 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ(0.01mΩ) 10-99mΩ: 100 μΩ(0.1mΩ) | Hoʻāʻo pololei -voltage -kū'ē
| ±0.2%rdg ±6dgt 0μΩ-250μΩ: 8%±6DGT 250μΩ-500μΩ: 3%±6DGT 500μΩ-100mΩ: 1%±6DGT |
Lako ikehu | 7.2V 2400mAhBati Li-ion | Ka manawa hana | ʻOi aku ma mua o 5 mau hola ma hope o ka hoʻopiha piha |
Ke ana i ka hoʻomanaʻo ʻikepili | 3000 pūnaewele | Kaiapuni hana | 0 ℃ i 40 ℃90% RH |
Hōʻike LCD | 320*240 pika TFT pā paʻi | Anana(hui nui) | L210*W110*H60 mm |
ʻupena paona(pūʻolo) | 2 kg | awa Com | USB mini |