GDYB-S20 ʻEkolu Pūnaehana Hoʻonaʻauao Meter Energy
ʻO GDYB moʻo ʻEkolu Equal Potential Multi-function Electric Energy Meter Test System ua hoʻomohala maikaʻi ʻia ke kolu o nā hanauna uila programmable ʻekolu ʻāpana uila uila multifunctional ho'āʻo ʻōnaehana e like me nā kūlana aupuni hou loa a me nā lula.Hoʻohana i ka insulated 0.01% kiʻekiʻe kiʻekiʻe 1: 1 ʻenehana transformer i kēia manawa, e hoʻokō i ka hoʻāʻo ʻana o ka volta i hoʻopili ʻia i loko o ka shunt ʻekolu mika mika.He kūpono ia no ka hoʻāʻo ʻana i nā ʻano mika uila ʻekolu o ka 0.2% a ma lalo (me ka sinusoidal reactive mika mana).He helehelena maikaʻi kona, nā hana piha a me ka hana maikaʻi loa.
GB/T 11150-2001 Mea hoʻāʻo no nā mika ikehu uila (neq IEC 60736)
JJG 307-2006 Nā Meka Electromechanical no ke ana ʻana i ka ikehu uila o kēia manawa.
ʻO JJG 596-1999 nā mika uila uila me nā mea uila
JJG 597-2005 Lako Hooiaio no ka AC Uila Uila Ana
DL/T 614-1997 mika watthour hana nui
DL/T 614-2007 Mea hoʻohana ana i ka uila (AC)
Kūlana kaiapuni
Ka wela kaiapuni hana: 23 ℃ ± 2 ℃.
Ka haʻahaʻa kaiapuni: 45%~75%.
Lako ikehu
Māhele hoʻokahi: AC220V±33V.Ka pinepine: 50±2.5Hz
ʻAno ʻAno: GDYB-S20 ʻEkolu Pūnaehana Hoʻāʻo ʻEkolu Uila ʻEleʻele.
Pololei pūnaewele: 0.05%.0.1%.
ʻO ka pololei mika maʻamau: 0.05% ʻEkolu māhele ʻekolu-hana mika maʻamau.
Voltage & ʻĀpana ana o kēia manawa:
Kaʻina uila puka: 57.7V/100V/220V/380V.
Kaʻina hana i kēia manawa: 0.005A, 0.025A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A.
Ka liʻiliʻi loa o kēia manawa: 1mA.pololei: ≤5%.
Hiki ke hoʻouka ʻia (20 mika)
Voltage pukana: 800VA.
Ka hopena o kēia manawa: 2500VA.
Voltage & hoʻoponopono i kēia manawa
Hiki ke hoʻololi ʻia: (0%~120%) x ke ana ʻana.
Hiki ke hoʻololi ʻia: 10%, 1%, 0.1%, 0.01%.
Hoʻoponopono pae:
Hiki ke hoʻololi ʻia: 0°~360°.
Hiki ke hoʻololi ʻia: 10°, 1°, 0.1°, 0.01°.
Hoʻololi pinepine:
Hiki ke hoʻololi ʻia: 45Hz~65Hz.
Hiki ke hoʻololi ʻia: 1Hz, 0.1Hz, 0.01Hz.
Paʻa mana puka: ≤0.05% / 120S.
Puke uila a me ka hoʻololi ʻana o kēia manawa:
Voltage: ≤0.5%.
I kēia manawa: ≤0.5%.
Nā hoʻonohonoho Harmonic:
Helu Harmonic: 2~21 manawa.
Maʻiʻo Harmonic: 2~21 manawa ≤40% i kēia manawa (pili i ka nalu kumu).
Volta 2 ~ 21 manawa ≤40% (pili i ka nalu kumu).
Māhele Harmonic: 0°~359.99°.
Mea hana nānā:
Ka pololei hōʻike mika maʻamau: Voltage: 0.01%.
I kēia manawa: 0.01%.
Mana: 0.01%.
Māhele: 0.01.
Ka pinepine: 0.01.
Hoʻokaʻawale ʻia 1:1 ka palena hoʻololi o kēia manawa:
Pono: 0.01%.
Ka mana puka: 60VA.
ʻO ke ana ʻana o kēia manawa: 1mA~120A (1:1).
Papa kuhikuhi hana nui
a) Pono: 0.01% (COS∮=0.5C…1…0.5L).
b) Ka helu pinepine: 50Hz/60Hz±5%.
c) Kūlana mua: 3×0.001-120A.
d) Ka lua o kēia manawa: 3×0.001-120A.
e) Haawe puka (kekahi māhele):
0.5W (ka laulā puka: 0.001-1A).
0.7V puʻunaue ʻia e ka waiwai o kēia manawa (hua hoʻopuka: 1-120A).
f) Puke uila hoʻouka: Max.0.5V (ka hoʻopuka o kēia manawa Max. 120A).
Ka nui o ka mea hoʻololi o kēia manawa: 265 x 200 x 240 mm (L x W x H).
Kaumaha: 12kg.
Anana:
Kumu mana: 610 x 800 x 1920mm (L x W x H).
Ka mika mika: 2350 x 750 x 1850mm (L x W x H).