ʻO GD2000D ka mea hōʻike kūʻē kūʻē
ʻO ka GD2000D digital insulation resistance tester i hana ʻia e kā mākou hui e hoʻohana ana i kahi ʻōnaehana hana ʻoihana hoʻokahi i hoʻopili ʻia.Hoʻohui maikaʻi ʻia ka ʻōkuhi analog kikohoʻe a me ka hōʻike pāʻālua kikohoʻe.ʻO kēia pūʻulu o nā mika he ʻano o nā pae puka uila (250V, 500V, 1000V, 2500V, 5000V, 10000V), ka mana nui, ikaika anti-interference, pointer analog a me ka hōʻike synchronous digital, AC a me DC hoʻohana pālua, hana maʻalahi, ka helu 'akomi o nā mea hōʻailona insulation (absorption ratio, polarization index), nā hopena ana like ʻole me ka hana anti-power down, etc. nā kaʻa uila, nā mana mana, nā kaula uila, a me nā mea hopu uila.
DL/T 474-2006 "Alakaʻi no ka ho'āʻo Insulation ma ka pūnaewele"
DL/T 845-2004 "Nā kiko'ī maʻamau no ke ana ʻana i nā mea hana kū'ē"
DL/T 846-2004 "Nā kikoʻī ʻenehana nui no nā mea hoʻāʻo uila kiʻekiʻe"
DL/T 596-2005 "Preventive test code forelectric power tools"
GB50150-2006 "Paʻamau no ka ho'āʻo lima lima o nā mea uila uila hoʻonohonoho ʻenehana"
GB/T16927.1~2-1997 "Nā hana ho'āʻo uila kiʻekiʻe"
GB4793-1984 "Ka hoʻonohonoho ʻana o ka insulation no ka hoʻoili uila kiʻekiʻe a me nā lako hāʻawi"
1. Voltage pukana (250V / 500V / 1000V / 2500V / 5000V) .Resistance range 0-200GΩ.
2. Hōʻike nā ʻano ʻelua i ke kūpaʻa insulation.
3. Ka helu 'akomi absorption ratio a me ka polarization index.
4. Hana maikaʻi, mālama mau i nā hopena ana 19times.
5. Auto-hoʻokuʻu koena kiʻekiʻe voltage ma hope o ka hoao ana.
6. AC/DC mana lako, me ka rechargeable pila a AC adapter.
7. Ka ikaika anti-interference hiki, paʻa a hilinaʻi heluhelu.
8. Hoʻolālā lawe, kūpono no ka hana hihiu.
9. ʻO kēia manawa pōkole ≥3mA, nā mea hana kūpono no ka hoʻāʻo ʻana i ke kūpaʻa insulation o ka transformer nui, inductor, generator, HV motors, capacitor uila, nā kaula a me ka hopu hopu.
'ikamu helu. | GD2000D | ||||||
Puke uila puka | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Ka pololei | Mahana | 23℃±5℃ | |||||
ʻO ke kūʻokoʻa | 250-5G ±5% | 50-10G ±5% | 1M-20G ±5% | 2.5M-50G ±5% | 5M-100G ±5% | ||
Nā laula ʻē aʻe: ±10% | |||||||
Puke uila puka | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Skaapuni hort | ≥3mA | ||||||
Lako ikehu | 8*ʻAno AA ʻano kiʻekiʻe hiki ke hoʻihoʻi i ka pākaukau a me ka mea hoʻopili waho | ||||||
Temp. & Humidity Hana | -10 ℃--40 ℃, ka haʻahaʻa pili 85% | ||||||
Waihona Temp. & Humidity | -20 ℃--60 ℃, ka haʻahaʻa pili 90% | ||||||
ʻO ka hoʻokaʻawale | ʻO Max.2000MΩ ke 1000VDC ka uila ma waena o ka pōʻai a me ka pūpū. | ||||||
E kū i ka uila | Hoʻopaʻa i 1min i ka wā e holo ai ka uila ma waena o ke kaapuni a me ka pūpū3kV50Hz SinVolta AC | ||||||
Anana | 230mm*190mm*90mm (L*W*H) | ||||||
Kaumaha | 3kg |
mea hōʻike kūʻokoʻa hoʻokaʻawale | 1 hoʻonohonoho |
Uea hoao | 1 apana |
Mea hoʻopili mana | 1 apana |
Uila mana | 1 apana |
Ke alakaʻi o ka mea hoʻohana | 1 kope |
Palapala | 1 kope |