GD3126A (GD3126B) Hōʻike Kūʻē Kūʻē 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Hoʻohana nui ʻia ka Insulation Resistance Tester i ka mālama ʻana i nā lako uila i loko o ka substation transformer, ka mana mana, a me nā mea ʻē aʻe. leakage o kēia manawa (Ix) a me ka absorption capacitance (Cx) o nā ʻano mea hana uila kiʻekiʻe, me ka switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.
●Hoʻohana i ka mana microcomputer, ka hana papa kuhikuhi a me ka hōʻike dot matrix LCD nui me ka hana paʻa.
●ʻO ka mana anti-interference ikaika, kūpono no ke ana ʻana i ke kaiapuni electromagnetic interference ikaika.
●ʻO ka mana nui, hiki ke hoʻokō i nā koi o ka volta kiʻekiʻe, ke kūpaʻa kiʻekiʻe, ka hoʻāʻo hoʻouka nui.
●Me ka shockproof, moisture-proof a me ka lepo-proof structure, e hoʻololi i ke kaiapuni hana paʻakikī.
●Hoʻohana maikaʻi, hōʻike i nā hopena pololei a me nā ʻano hoʻololi ʻikepili.
●ʻO ka hana palekana kūpono, hiki ke pale i ka hopena o ke kaapuni pōkole a me ke ana capacitance koena voltage.
●5 mau ʻanuʻu hoʻopuka uila o 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 mau ʻanuʻu puka uila o 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Hiki ke hoʻololi mau ʻia ka volta kiʻekiʻe o kēlā me kēia ʻanuʻu mai ka zero.
●Hiki ke hoʻololi mau ʻia ka uila kiʻekiʻe.
●Ana 'akomi o R15, R60, R600, helu 'akomi o ka lākiō absorption, polarization index.
●ʻO 0~10TΩ (0~20TΩ) ka nui o ke ana kūʻē kūʻē, ka laulā hoʻololi ʻakomi.
●Ana 'akomi o ka wela ambient, ea humidity a me ka manawa hoao.
●Hōʻike i ka manawa hoʻāʻo, nā ʻōlelo aʻoaʻo buzz i kēlā me kēia 15 kekona, 5 mau minuke me ka hana ʻole e hoʻopau koke.
●Hoʻokuʻu aunoa i ka volta kiʻekiʻe ma hope o ke ana ʻana, ʻaʻole ʻoi aku ka manawa hoʻokuʻu ma mua o 30 kekona.
●Ka mālama ʻana o 60 mau pūʻulu o ke ana ʻana i nā hopena, nonvolatility no 20 mau makahiki.
●Me ka RS232 serial interface, hiki ke kamaʻilio ʻikepili me ke kamepiula.
●Me ka mīkini paʻi waho, hiki ke paʻi i nā hopena ana.(koho)
●Hōʻike ʻia ka volta o ka hāpana i hoʻopaʻa ʻia ma mua o ka hoʻāʻo ʻana a loaʻa iā ia nā hōʻailona kūpono.
●Hoʻonohonoho ʻia ka manawa hoʻāʻo, hoʻopau ʻakomi i ke ana;
●Hiki ke ʻike i ka leakage o kēia manawa Ix a me ka mana absorption Cx.
Ua helu ʻia nā ʻanuʻu uila hoʻāʻo | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Haʻihaʻi uila puka | ±5% | ||||||
Palena kūʻē | palena luna | 500GΩ~10TΩ | |||||
palena haʻahaʻa | 0.1MΩ | ||||||
Papa pololei | 5.0 papa | ||||||
Kuhi hewa hōʻike uila kiʻekiʻe | ±( 5%•Ux + 1kipili ) | ||||||
Leakage i kēia manawa Ix ana laula a me ka hewa | 0.1nA~9.9mA 5% | ||||||
Absorption capacitance Cx ana ana a me ka hewa | 0.1pF~99ɥF 5% | ||||||
Hewa ke ana ana wela | ±0.5 ℃ | ||||||
Haʻahaʻa ana hewa | ±2%RH | ||||||
Kaapuni pokole | <6mA | ||||||
Nani uila | <3% | ||||||
Ka manawa hoao | A hiki i 99 mau minuke | ||||||
ʻO ke kūʻokoʻa | > 500 MΩ (ma waena o ka uea hoʻāʻo a me ka hihia) | ||||||
E kū i ka uila | AC10.0kV 50Hz 1min (ma waena o ka uea hoʻāʻo a me ka hihia) | ||||||
Lako ikehu | 12V lithium pākaukau | ||||||
ʻO ka manawa lawelawe pākaukau ma hope o ke kau ʻana hoʻokahi | 30 mau lā 10 mau manawa DAR & 5 mau manawa PI ho'āʻo i kēlā me kēia lā | ||||||
ʻO ka mahana hana a me ka haʻahaʻa | 0 ℃ ~ + 40 ℃ < 85%RH | ||||||
ʻO ka mahana mālama a me ka haʻahaʻa | - 20 ℃ ~ + 50 ℃ < 90%RH | ||||||
Lako ikehu | 220V AC 50Hz | ||||||
Ana (mm) | 325 (L)*250(W)*130(H) | ||||||
Kaumaha | 3.7 kg | ||||||
Kuʻi ana hewa | |||||||
ʻanuʻu uila | 250 V | 500 V | 1.0 kV | 2.5 kV | 5.0 kV | 10KV | |
±( 3%·Rx + 1d ) | 1GΩ | 2GΩ | 4GΩ | 10GΩ | 20GΩ | 40GΩ | |
±( 5%·Rx + 1d ) | 10GΩ | 20GΩ | 40GΩ | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
±( 10%·Rx + 2d ) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ | 2 TΩ | 4TΩ | |
±( 25%·Rx + 2d ) | 500GΩ | 1TΩ | 2TΩ | 5TΩ | 10TΩ | 20TΩ |
mea hōʻike kūʻokoʻa hoʻokaʻawale | 1 hoʻonohonoho |
E ho'āʻo i ke kaula hoʻohui no ka pahu L (ʻulaʻula) | 1 kumu (1 ʻāpana) |
E ho'āʻo i ka uwea hoʻohui no G (Green) | 1 kumu (1 ʻāpana) |
E ho'āʻo i ke kaula hoʻohui no ka pahu E (ʻeleʻele) | 1 kumu (1 ʻāpana) |
3APower adapter (No ka lako mana paʻi a me ka hoʻouka ʻana i nā mea kani) | 1 piece (1 ʻāpana) |
RS232 laina kamaʻilio Serial | 1 kumu (1 ʻāpana) |
mea hoʻohanas alakai | 1 kope (1 ʻāpana) |
Hoike Hoao | 1 kope (1 ʻāpana) |
L
5. Buzzer 6. ʻIke wela a me ka haʻahaʻa 7. Pihi ESC 8. Pihi UP
9. Pihi ho'oka'awale 10. Pihi IHO 11. Pihi OK12. Kiʻekiʻe voltage hoʻoponopono kī
13. RS232 interface 14. Hoʻololi mana15. Socket hoʻouka