GDOH-II Insulating Oil Gas Content Tester
ʻO GDOH-II Insulating Oil Gas Content Tester he hanauna hōʻike hōʻike hou i lawe ʻia mai ka mea ʻike pono kiʻekiʻe a me ka ʻenehana sensor hou loa.Hoʻokumu ʻia ia ma ka DL423-91 mana ʻoihana mana a me nā kūlana ʻāina kūpono.ʻOi aku ka hana, ʻoi aku ka paʻa a me ka hilinaʻi i ka hana, maʻalahi e hana a ʻoi aku ka kūpono no ka hoʻoholo ʻana i ka ʻike kinoea i loko o nā mea hana ʻaila ultra-high voltage.He mea ho'āʻo maikaʻi loa ia no ka hale hoʻokolohua.
●Ke pale nei ka hale metala āpau i nā pilikia o ka palupalu a me ka hoʻopaʻa maikaʻi ʻole o ka mea hōʻike aniani.
●ʻO ka hoʻohana ʻana i ka ʻike kiʻekiʻe a me ke kūpaʻa kiʻekiʻe i lawe ʻia mai ka sensor ʻokoʻa ʻokoʻa e ʻoi aku ka pololei o ka ʻikepili hōʻike.
●Aia i loko o ke kaapuni hoʻāʻo nā mea ʻike e ana i ke kaomi o ka lewa a me ka mahana ambient.ʻAʻohe mea i hea ʻoe, hiki iā ʻoe ke ana ʻakomi i ka mahana ambient a me ke kaomi o ka lewa ma kou wahi, e hoʻololi ʻokoʻa i ka ʻike kinoea ma 0 ° ma lalo o ke kaomi lewa maʻamau, a hōʻike pololei ma ka pale LCD
●ʻO ka polokalamu hoʻāʻo anti-standard hoʻāʻo kinoea kū hoʻokahi e hiki ai iā ʻoe ke nānā maʻalahi inā calibrated a ana ʻia paha ka mea kani.
●He pōkole ka manawa ho'āʻo aila, a ʻo ka manawa hoʻāʻo āpau e lawe wale ma kahi o 7 mau minuke.
●I ka wā o ka hoʻāʻo ʻana, hoʻokele ʻia ka hana o ka ʻōpala e ka mea hana e like me ka mokuʻāina, kahi e hoʻemi nui ai i ka walaʻau a hoʻolōʻihi i ke ola lawelawe o ka ʻōpala.
●Hiki i ka mea kani ke hoʻopaʻa i nā ʻikepili hoʻāʻo hope loa, a mālama i ka manawa hoʻāʻo, ka mahana, ke kaomi lewa, a me nā mea ʻē aʻe, i hiki iā ʻoe ke nānā maʻalahi i ka ʻikepili.
●Me ka hana paʻi, hiki iā ʻoe ke paʻi i ka ʻikepili hōʻike e like me kāu mau koi.
●Hiki ke koho ʻia ka ʻaila ʻaila like no ka helu o nā hoʻokolohua.Ma hope o ka pau ʻana o ka hoʻāʻo, e hōʻike ʻia nā hopena hoʻokahi a me ka awelika ma ka hōʻike a paʻi ʻia paha.
Kiʻekiʻe-pololei uila puʻe puʻe | ʻAʻole emi ka hopena ma lalo o 0.1%. | |
palena ʻike liʻiliʻi | ʻAʻole iʻoi aku ma mua o 0.2%. | |
Ka pololei | ʻAʻole pono e ʻoi aku ka hewa pili o nā hualoaʻa ana hou ʻia ma mua o kēia mau waiwai: | |
Maʻiʻo kinoea i loko o ka ʻaila (haʻi helu), % | Kuhi hewa,% | |
< 0.5 | 10 | |
0.5-1.0 | 8 | |
1.0~3.0 | 5 | |
>3.0 | 3 | |
Degassing lumi wela mana laula | 5 ℃ a 70 ℃ ma luna o ka mahana wela | |
lako mana hana | AC 220V±10%, 50Hz | |
Anana | 450*325*350 mm | |
Kaumaha | Ma kahi o 20kg |
mea hōʻike | 1 hoʻonohonoho |
Uila mana | 1 apana |
ʻO ka pauma a me ka mea hoʻohui | 1 hoʻonohonoho |
3mm paipu kila kila | 1.5m, 0.5m |
Mea hoʻopili syringe | 1 hoʻonohonoho |
Fuse 10A | 3 apana |
M8×1 nut | 10 apana |
Sila | 10 apana |
Paʻa syringe | 1 apana |
1mL calibration syringe | 1 apana |
ʻO ka pauma ʻūhā Rotary vane | 1 hoʻonohonoho |
Papa kuhikuhi | 1 kope |
palapala hōʻoia huahana | 1 kope |
Hōʻike hoʻokolohua hale hana | 1 kope |
Papa helu hoʻopili | 1 kope |