Nā huahana

  • GDP-713PM SF6 Gas Dew Point Mea Hōʻoia

    GDP-713PM SF6 Gas Dew Point Mea Hōʻoia

    GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester ua hoʻolālā kūikawā ʻia no ka SF6 kinoea micro moisture detection.ʻO ka hui pū ʻana o ka ʻenekona dew point kiʻekiʻe a me ka ʻenehana hoʻokele uila naʻauao e hoʻohana maikaʻi ʻia i ke ana pololei ʻana o ka hau ma lalo o nā kūlana kaiapuni.

    Hoʻokumu ʻia ke ana ʻana o ka hau ma ke kumu o ke aniani anuanu.Hoʻopili ʻia ka mahu wai i loko o ke kinoea i ana ʻia i ka wai a i ʻole ka hau ma ka ʻili aniani ma o ka semiconductor cold reactor cooling.Ke hiki aku i ka equilibrium ʻelua o ka wai i loko o ke kinoea, ana ʻia ka mahana o ka ʻili aniani i kēia manawa, ʻo ia ka lae hau a i ʻole ka hau.

    Hoʻohālikelike ʻia me nā ʻano ʻano ʻē aʻe o ka mika kiko hau, ʻoi aku ka pololei o ke aniani aniani dew point mika i ka mahana o ka hau, a i ka manawa like me nā hiʻohiʻona o ke ana maikaʻi repeatability, kūpaʻa a hilinaʻi nā hopena ana, a maʻalahi ka hana.

    GDP-713PM ʻano hoʻoluʻu lawe lima SF6 kinoea dew point mika he mea hana maʻamau no ke ana ʻana o ka haʻahaʻa ma nā kahua o ka mana uila, gas, meteorology, electronics, petroleum, chemical industry, ana, etc. He koho kūpono no ka hoʻokumu ʻana i kahi kūlana haʻahaʻa. mea hana.

  • GDP-8000CM SF6 Gas Dew Point Mea Hōʻoia

    GDP-8000CM SF6 Gas Dew Point Mea Hōʻoia

    Hoʻolālā kūikawā ʻia ʻo GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester no ka SF6 kinoea micro moisture detection i hoʻohana ʻia ma ka ʻāpana wela holoʻokoʻa o ka ʻoihana mana, i hoʻokumu ʻia ma Stryn refrigeration a me chilled mirror ana kumu.

  • GDQC-55A SF6 Gas Vacuuming a me ka mīkini hoʻopiha piha

    GDQC-55A SF6 Gas Vacuuming a me ka mīkini hoʻopiha piha

    Hoʻohana nui ʻia ʻo GDQC-55A SF6 Gas Vacuuming and Filling Machine no ka hoʻokomo ʻana, ka hana, a me ka mālama ʻana o 35kV ~ 220kV ceramic column SF6 circuit breakers, transformers a me nā mea uila SF6 ʻē aʻe.He mea paʻa ia, i kau ʻia ma luna o ke ʻano metala ikaika, a hele wale ma nā alanui ʻiliʻili.

    He kūpono ia no nā lako uila SF6, mea hana GIS a me ke keʻena noiʻi.

  • Pūnaehana ho'āʻo ʻāpana ʻāpana GIT moʻo

    Pūnaehana ho'āʻo ʻāpana ʻāpana GIT moʻo

    Hoʻohana nui ʻia ka moʻo GIT no ka uila kiʻekiʻe, ka nui o nā lako mana GIS i hoʻopaʻa ʻia i ka hoʻāʻo ʻana i ka volta, ka hoʻāʻo ʻana i ka ʻāpana a me ka hoʻāʻo pololei ʻana o ka GIS transformer, kūpono no ka substation GIS, ka mea hana mana GIS, ka mea hana insulator uila.

     

     

     

     

     

     

  • GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

    GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

    ʻO GDSL-A Series 3-phase Primary Current Injection Test Set me Temperature Test ka mea kūpono no ka hoʻāʻo ʻana i nā mea kiʻekiʻe o kēia manawa i ka mana a me ka ʻoihana uila, i hoʻohana ʻia i nā mea kanu mana, nā keʻena hoʻoili mana, nā hana uila a me nā keʻena noiʻi, me nā hiʻohiʻona. o ka liʻiliʻi liʻiliʻi, ke kaumaha māmā, ka hoʻohana maʻalahi a me ka mālama.

     

     

     

     

     

  • Pūnaehana hoʻāʻo ʻo GDCY Impulse Voltage (100kV-7200kV)

    Pūnaehana hoʻāʻo ʻo GDCY Impulse Voltage (100kV-7200kV)

    Hoʻohana nui ʻia ʻo Impulse Voltage Test System no ka hoʻokō ʻana i ka hoʻāʻo ʻana o ka uila uila uila, ʻokiʻoki i ka hoʻāʻo impulse a me ka hoʻololi ʻana i ka hoʻāʻo impulse ma nā mea HV e like me nā transformers, surge arrester, insulators, bushings, capacitors, a me nā hoʻololi.Hiki iā ia ke hoʻohua i ka nalu uila maʻamau, ka nalu hoʻololi, ka nalu ʻoki ʻana me ka laulā ākea a me ka ikehu.

     

     

     

  • Pūnaehana ho'āʻo ʻāpana ʻāpana GDYT

    Pūnaehana ho'āʻo ʻāpana ʻāpana GDYT

    Hoʻohana nui ia i ka hana uila, nā keʻena hana mana, nā keʻena noiʻi a me nā kulanui.

     

     

     

  • GDBT-1000kVA Papa Ho'āʻo Transformer

    GDBT-1000kVA Papa Ho'āʻo Transformer

    Hiki i ka ʻōnaehana hoʻāʻo GDBT Transformer ke hana i nā hoʻokolohua maʻamau no nā mea hoʻololi, me ka hoʻāʻo No-load a me ka hoʻouka ʻana, Induced voltage test, Power frequency withstand voltage test, partial discharge test, DC resistance test, turn ratio test, temperature rise test etc.

  • GDYB-S20 ʻEkolu Pūnaehana Hoʻonaʻauao Meter Energy

    GDYB-S20 ʻEkolu Pūnaehana Hoʻonaʻauao Meter Energy

    ʻO GDYB moʻo ʻEkolu Equal Potential Multi-function Electric Energy Meter Test System ua hoʻomohala maikaʻi ʻia ke kolu o nā hanauna uila programmable ʻekolu ʻāpana uila uila multifunctional ho'āʻo ʻōnaehana e like me nā kūlana aupuni hou loa a me nā lula.

     

  • GDHX-9500 Māhele ʻIke

    GDHX-9500 Māhele ʻIke

    Hoʻohana nui ʻia ʻo GDHX-9500 Phase Detector i nā laina mana uila, ka hoʻonohonoho ʻana i ke kaʻina a me ke kaʻina hana i ka substation, me nā hana nui e pili ana i ka nānā uila, ka hoʻokaʻina ʻana a me ke ana ʻana o ka pae.

  • GDHX-9700 Māhele ʻIke

    GDHX-9700 Māhele ʻIke

    Hoʻohana nui ʻia ka GDHX-9700 Phase Detector i nā laina mana uila, ka ʻāpana, a me ka hoʻonohonoho ʻana o ke kaʻina hana i ka substation, me nā hana nui e pili ana i ka nānā uila, ka hoʻokaʻina ʻana a me ke ana ʻana o ke kaʻina.

  • ʻO GDND-800 mea hoʻāʻo kiko hau

    ʻO GDND-800 mea hoʻāʻo kiko hau

    ʻO Transformer oil freezing point tester nā hiʻohiʻona o ka hoʻolālā hoʻolālā nani a me ke kaʻina hana kūʻokoʻa.Kūlike ia i nā kūlana GB/T 3535 a me GB/T510 a hoʻohana ʻia e hoʻoholo i ka wahi ninini o nā huahana ʻaila.

E hoʻouna i kāu leka iā mākou:

E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou