GDCR3000 Kikohoʻe Honua Kūʻē Kūʻai
ʻO GDCR3000 Digital Earth Resistance Tester ua hoʻolālā kūikawā a hana ʻia no ke ana ʻāina, e hoʻohana ana i ka ʻenehana hou a me ka micro-processing ʻenehana, 3-pole a i ʻole 2-pole ala no ke ana ʻana i ka honua, me kahi hana kūʻokoʻa o ka hōʻoia ʻana i ka uea, hiki ke hoʻopilikia. a me ka hiki ke hoʻololi i ke kaiapuni, e hōʻoia i ka precision kiʻekiʻe, ke kūpaʻa kiʻekiʻe a me ka hilinaʻi no ka lōʻihi o ke ana, i hoʻohana nui ʻia i ka mana uila, telecommunications, meteorology, oil field, construction, protection lighting, industrial electrical equipment and other earth ground resistance. ana ana.
Hana ana | Kaulana | Ka pololei | Olelo Hooholo |
Kūleʻa honua | 0.01Ω~20Ω | ±2%rdg ±3dgt (Ke kū'ē honua kōkua 100Ω±5% , uila uila<10V) | 0.01Ω |
0.1Ω~200Ω | 0.1Ω | ||
1Ω~2000Ω | 1Ω | ||
Volta honua | 0~600V AC | ±1%rdg ±3dgt | 1V |
Hana | Ana kū'ē honua, ana voltage i ka honua, ana kū'ē waiwai ha'aha'a |
Lako ikehu | DC 9V(Zi-Mn pākahi maloʻo R14S 1.5V 6 PCS) |
Kukui hope | Hiki ke hoʻohana ʻia ke kukui ʻulaʻula uliuli, kūpono no ka hoʻohana ʻana ma kahi pouli. |
Ana Ana | Ana pololei 3-pole, ana 2-pole ma'alahi |
Ana Ana | Kūleʻa ʻāina honua: helu ʻia ke ʻano hoʻololi-pole o kēia manawa, ana i kēia manawa20mA Max. Voltage i ka honua: hoʻoponopono waiwai maʻamau |
ʻAno ʻIkepili | Waiwai maʻamau, ka nui, ka liʻiliʻi |
Hōʻoia Kūʻē Uea | E hōʻalo i ka hewa i hoʻokumu ʻia e ka hoʻāʻo ʻana i ka uea ʻaʻole i hoʻokomo piha ʻia i loko o ka interface tester a i ʻole ma muli o ka hoʻopili maikaʻi ʻole ʻana a i ʻole ka hoʻololi ʻana a i ʻole ka hoʻolōʻihi ʻana o nā mea hoʻohana i nā uea hoʻāʻo, e ʻoi aku ka pololei no ke ana ʻana i ke kūpaʻa honua. |
ʻAno hōʻike | 4-kikohoʻe super-nui LCD hōʻike, polū pale kuapo |
Hōʻailona ana | I ka wā e ana ana, hōʻike ʻia ke kukui uila, hōʻike LCD helu i lalo |
Anana LCD | 128mm×75mm;kahua hōʻike:124mm×67mm |
Anana | L×W×H: 215mm×190mm×95mm |
Uea hoao | ʻEkolu uea: ʻo kēlā me kēia no Red 20m, Yellow 10m, a me Green 5m |
Uea hoao maalahi | 2 uea: kēlā me kēia no Red 1.6m a me Green 1.6m |
Auxiliary earthing rod | 2 PCS: Φ10mm×150mm |
Ana Ana | Voltage i ka honua: ma kahi o 3 manawa / kekona;ka pale ʻana o ka honua: ma kahi o 5 kekona/manawa |
Ana Manawa | Ma luna o 5000 manawa (Ke ana ʻana i ka 10Ω no hoʻokahi manawa ma ka laulā 20Ω a hoʻomaha no30s) |
Kaapuni Kaapuni | Ke ana ana i ka volta i ka honua: ana ma lalo o AC 600V |
USBIkepili | LoaʻaUSBHiki ke hoʻoili ʻia ka ʻikepili i ke kamepiula, mālama ʻia a paʻi ʻia paha. |
Uea kamaʻilio | Hoʻokahi ʻāpana oUSBuea kamaʻilio, me ka lōʻihi 1.5m |
Waihona ʻikepili | 400 sets, hōʻike uila "FULL" ikona e hōʻike i ka piha o ka waiho ʻana |
Paʻa ʻikepili | Hana paʻa ʻikepili: hōʻike ikona "HOLD". |
Heluhelu Ike | Hana heluhelu ʻikepili: "READ" ikona hōʻike |
Hōʻike Hoʻohāhā | ʻOi aku ka nui o ke ana ʻana i ka hana overflow: "O" ikona hōʻike |
Hana Alala | Ke ana ʻana i ka waiwai ma mua o ka waiwai hoʻonohonoho hoʻāla, aia ka ʻōlelo hōʻailona "Toot-toot-toot". |
Voltage Battery | Ke emi iho nei ka uila uila a hiki i ka 7.8V, e hōʻike ʻia ke kiʻiona haʻahaʻa o ka pila, e hoʻomanaʻo anauku. |
Hoʻohana mana | Kukui hope: 25mA Max |
Kūlana: 25mA Max (Paʻa ke kukui hope) | |
Ana ana:200mA Max (Paʻa ke kukui hope) | |
Kaumaha | mea hōʻike:1325g (me ka pākaukau) |
Uea hoao:847g(me ka hoʻāʻo wale ʻana i nā uwea) | |
Kookoo honua kōkua:468g(2 PCS) | |
ʻeke mika:915g | |
Ka Mahana Hana a me ka Humidity | -10 ℃~40℃;malalo o 80%rh |
ʻO ka mahana mālama a me ka haʻahaʻa | -20 ℃~60℃;malalo o 70%rh |
ʻO ka hoʻomalu ʻana i ka ukana | Ke ana ʻana i ke kū ʻana o ka honua: ma waena o kēlā me kēia pānaʻi o EP, EC, AC 280V/3 kekona |
Kū'ē Kū'ē | Ma luna o 10MΩ (ma waena o ke kaapuni a me ka pā he 500V) |
Paʻa Voltage | AC 3700V/rms (Ma waena o ke kaapuni a me ka pā) |
Nā hiʻohiʻona electromagnetic | kahua electromagnetic alapine ʻole |
ʻAno Palekana | IEC61010-1,IEC1010-2-31,IEC61557-1,5,IEC60529(IP54),haumia etc. 2,CATⅢ 300V |