ʻO GDCR-3200C Paʻa Paʻa ʻelua Multifunctional Earth Resistance Tester
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester ua hoʻolālā kūikawā ʻia a hana ʻia no ke ana ʻana o ka pae ʻana o ke kūpaʻa ʻāina, ka pale ʻana o ka lepo, ka voli grounding, ka laina leakage o kēia manawa, ka AC a me ke kūpaʻa DC.Hoʻohana ka mea hana i ka ʻenehana hana kikohoʻe holomua, me ke ʻano 2-wire, 3-wire method, 4-wire method, ke ʻano koho, ke ʻano hoʻopili pālua a me nā ʻano ana ʻē aʻe;Hoʻokomo i ka ʻenehana FFT (Fast Fourier Transform), ʻenehana AFC (Automatic Frequency Control), me ka mana kūʻokoʻa kūʻokoʻa kūʻokoʻa a me ka hoʻololi ʻana i ke kaiapuni, kiʻekiʻe kiʻekiʻe o ka hoʻāʻo pinepine ʻana, e hōʻoiaʻiʻo ana i ka pololei kiʻekiʻe, ke kūpaʻa kiʻekiʻe a me ka hilinaʻi kiʻekiʻe no ke ana lōʻihi. ʻO ka hoʻolālā paʻa ʻana o kēia manawa, hiki ke hana i nā ʻano koi like ʻole, hiki ke ana i ke kumu kūʻē kūʻē o ka honua nui i lalo o ke alakaʻi, hiki ke ana i ke kumu kūʻē kūʻē o ka helu hoʻokahi a me ka pae ʻāina a me nā ʻano ʻano paʻakikī paʻakikī. ʻAʻole pono e hoʻokaʻawale i kekahi pole honua pili pili i ke ana ʻana i ka ʻōnaehana kumu, hoʻomaikaʻi nui i ka maʻalahi o ke ana ʻana, no ka mea, hāʻawi ka hoʻāʻo ʻana i ka hana ʻana i kahi hopena kūpono.
ʻO GDCR3200C Double Clamp Multifunctional Earth Resistance Tester ka mea i haku ʻia me ka mīkini hoʻokipa, ka hoʻopili ʻana i kēia manawa (pālua pālua), nā uea hoʻāʻo, ke koʻokoʻo koʻikoʻi kōkua, nā polokalamu ʻikepili a me nā uea kamaʻilio a pēlā aku.ʻO ka hōʻike LCD nui o ka mīkini hoʻokipa me ke kukui keʻokeʻo a me ka hōʻailona kiʻi pahu i hiki ke ʻike maopopo ʻia.Loaʻa i ka mea hōʻike ka hana mālama, ka hana uaki, a mālama pono i nā hui 2000 o nā hopena hoʻāʻo e loaʻa ana ka lā a me ka manawa.Ma hope o ka hoʻokomo ʻana o APP, hiki iā ia ke hoʻāʻo a heluhelu i nā moʻolelo hoʻāʻo ma ka pahu kelepona, e lawe mai i kahi ʻike hou.Hāʻawi ka mea hōʻike i ke kikowaena USB, a hiki ke hoʻouka ʻia ka ʻikepili i mālama ʻia i ka PC ma o ka USB interface.Hiki i ka polokalamu kamaʻilio ke hoʻomaopopo i nā hana o ka heluhelu, kūkākūkā, mālama, hōʻike a paʻi i ka ʻikepili moʻolelo mōʻaukala.Hoʻohana nui ʻia i ka mana, kelepona, meteorology, ʻaila ʻaila, kūkulu, pale uila a me nā lako uila ʻoihana.
●Hoʻolālā kūʻokoʻa o ke kukui hōʻailona jack, hōʻike pololei i ke kūlana jack, pale i ka hewa hana.
●Hōʻike ʻia nā ʻano hoʻāʻo like ʻole, e maʻalahi a wikiwiki ka hana.
●Loaʻa i ka mea hōʻike ka hana kamaʻilio Bluetooth a kākoʻo i ka ʻōnaehana Android.Hiki i nā mea hoʻohana ke hoʻohana i ka pahu kelepona e hoʻāʻo ai i ka hana a i ʻole heluhelu i nā hopena hōʻike i loaʻa ka lā a me ka manawa maʻalahi.
●Hoʻohana ka pahu mea kani i ka pahu pale wai, ikaika, palekana a paʻa no ka anti-collision, anti-fall a me ka wai (pale pale IP65), kūpono loa no ka hoʻohana ʻana i nā kahua kūkulu waho.
●Hoʻolako ʻia ka mika me ka nui o ka pahu pahu lithium rechargeable.A me ka USB interface e hoʻouka i ka hana ʻikepili.
Kūlana kumu & Kūlana hana
Ka nui o ka mana | Kūlana Kūlana | Nā Kūlana Hana | ʻŌlelo |
ʻO ka Temp | 23℃±1℃ | -10 ℃-40 ℃ | ---- |
ʻO ka haʻahaʻa haʻahaʻa | 40%-60% | <80% | ---- |
Voltage Hana | 7.8V±0.1V | DC 7.8V±0.6V | ---- |
Kūʻē Honua kōkua | <100Ω | <5kΩ | |
Voltage Interference | Pono e pale aku | <20V | |
Keia manawa | Pono e pale aku | <2A | |
Ka mamao Electrode ke ana ana ia R | a>5d | a>5d | |
Ka mamao Electrode ke ana ana i ka ρ | a>20h | a>20h |
Hōʻike kikoʻī
Hana | E ana i ka pale ʻana i ka honua, resistivity lepo;ʻO ke kūpaʻa DC, ka uila honua, ke ʻano o kēia manawa, ka leakage | |
Lako ikehu | DC 7.4V 2600mAh pākaukau lithium hiki ke hoʻouka hou ʻia, piha i ka 8.4V | |
Kukui hope | Hiki ke hoʻopaʻa ʻia ke kukui hope, kūpono no nā wahi polū | |
Ana Ana | DC kū'ē | ʻO ke ʻano hana 2-uea kūʻē DC |
ʻO ke ʻano 4-wire kūʻē DC | ||
Kūleʻa honua | Kūleʻa honua 2-wire ala | |
Kūleʻa honua 3-wire ala | ||
Kūleʻa honua 4-wire ala | ||
ʻO ke ʻano hoʻopaʻapaʻa hoʻokahi 3-uea (ke ʻano koho) pale honua. | ||
ʻO ke ʻano o ka hoʻopaʻa ʻana o ka honua 4-wire (ke ʻano koho) | ||
Kūleʻa honua double clamp method | ||
Ka pale ʻana o ka lepo (Wenner method) | ||
Ke au honua | Ana pipili o keia manawa | |
Volta honua | Hoʻoponopono maʻamau | |
Nalu Voltage Hoao | ʻAle kino | |
Ka pinepine hoao | 128Hz/111Hz/105Hz/94Hz(AFC) | |
ʻO ka hoʻāʻo pōkole i kēia manawa | AC 250mA max | |
Kaapuni hamama i keia manawa | AC 40V ka nui | |
Ka mamao Electrode | 1m-100m | |
ʻAno hōʻike | 4-heluhelu LCD nui, me ka pale kuapo | |
Hōʻailona Ana | I ka wā o ke ana ʻana, hōʻailona uila LED, hōʻike helu helu LCD | |
ʻO ka nui o ke kiʻi LCD | 128mm×75mm | |
Wahi hōʻike LCD | 124mm×67mm | |
Anana Mea Hana | 280mm(L) X 260mm(W) X 160mm(H) | |
Nui CT | 223mm X 120mm X 39mm | |
Uea hoao | 4 uea: ʻo kēlā me kēia no ka ʻulaʻula 20m, ʻeleʻele 20m, melemele 10m, a me ka ʻōmaʻomaʻo 10m | |
Uea hoao maalahi | 2 uea: kēlā me kēia no ka ʻulaʻula 1.6m a ʻeleʻele 1.6m | |
Auxiliary Grounding Rod | 4 PCS: Φ10mm X150mm | |
Paʻi o kēia manawa | 2 PCS : 1 pulupulu uliuli-eleele a me 1 pulupulu ulaula-eleele | |
Paʻi Caliber | Φ70mm | |
Uea Lead Paʻi | 2m | |
Ana Ana | AC i kēia manawa: ma kahi o 2 mau manawa / kekona | |
Ka Voltage Honua: ma kahi o 2 manawa / kekona | ||
Kū'ē honua: ma kahi o 7 kekona/manawa | ||
Ana Manawa | ʻOi aku ma mua o 5000 mau manawa (Ka hoʻāʻo pōkole pōkole, ʻoi aku ka manawa ma kahi o 30 kekona) | |
Laina Voltage | Ana ma lalo o AC 600V | |
Pāʻani Kūkākūkā | Bluetooth module, USB interface, hiki ke hoʻouka i ka ʻikepili i ke kamepiula, mālama ʻia a paʻi ʻia paha. | |
Uea kamaʻilio | Uea kamaʻilio USB x1pcs, me ka lōʻihi 1.5m | |
Paʻa ʻikepili | Hana paʻa ʻikepili: hōʻike hōʻailona "HOLD". | |
Waihona ʻikepili | 2000 pūʻulu, “MEM” hōʻailona mālama, "FULL" hōʻailona hōʻike flash piha | |
Loaʻa ʻikepili | Hana heluhelu ʻikepili: "READ" hōʻike hōʻailona | |
Hōʻike Hoʻohāhā | Hana ʻoi aku ka nui o ke ana ʻana: "OL" hōʻailona hōʻailona | |
Hōʻailona Haʻahaʻa o kēia manawa o ka paʻi o kēia manawa | ʻO ke ana me ke ʻano koho a i ʻole ka hoʻopili pālua, ʻoi aku ka haʻahaʻa o ka hōʻailona o kēia manawa i loaʻa e CT2 ma mua o 0.5mA, e hōʻike ʻia "", a pono e nānā i ke kuhikuhi ʻana o ka ʻōkuhi CT2 o kēia manawa. | |
Ho'āʻo hoʻopilikia | ʻIke ʻakomi o nā hōʻailona hoʻopilikia, hōʻailona hōʻailona "NOISE" inā ʻoi aku ka kiʻekiʻe o ka volta interference ma mua o 5V | |
Ho'āʻo Kuʻuna Kokua | Me ka hana ho'āʻo kūʻē kūʻē ʻāina kōkua, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
Hana Alala | ʻOi aku ka waiwai o ke ana ʻana ma mua o ka waiwai hoʻonohonoho hoʻāla, e ʻike ʻia ke kani ala "Toot-toot-toot". | |
Voltage Battery | ʻOiai e emi ana ka uila uila a puni 7.2V ± 0.1V, e hōʻike ana i ka hōʻailona haʻahaʻa o ka pākaukau, a me ka hoʻomanaʻo ʻana e hoʻololi i ka pā. | |
Pani 'akomi | Pani 'akomi ma hope o 15 mau minuke o ka mana | |
Hana i kēia manawa | ʻO ke kukui hope: 25mA Max (ka hoʻohana ʻana i ka mana kukui backlight wale nō) | |
Ke kū nei: 25mA Max (Ua pio ke kukui hope ma hope o ka hoʻā ʻana) | ||
Ana: 150mA Max (Paʻa ke kukui hope) | ||
Kaumaha | Mea ho'āʻo: 2290g | |
Paʻi o kēia manawa: 1100g (2 mau ʻāpana) | ||
Ka huina kaumaha: 6800g (me nā mea pono a pau) | ||
Ka Mahana Hana a me ka Humidity | -10 ℃-40 ℃, ma lalo o 80%rh | |
ʻO ka mahana mālama a me ka haʻahaʻa | -20 ℃-60 ℃, ma lalo o 70%rh | |
Papa Palekana | IP65 (pani i ka hihia) | |
ʻO ka hoʻomalu ʻana i ka ukana | E ana i ke kū'ē honua: ma waena o kēlā me kēia pānaʻi o C(H)-E,P(S)-ES, AC 280V/3 kekona | |
Kū'ē Kū'ē | Ma luna o 20MΩ (ma waena o ke kaapuni a me waho o ka pūpū he 500V) | |
Paʻa Voltage | AC 3700V/rms.(Ma waena o ke kaapuni a me waho o ka pūpū) | |
Nā hiʻohiʻona electromagnetic | IEC61326(EMC) | |
ʻAno Palekana | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,Polusi 2); IEC61010-031; IEC61557-1(Pale honua); IEC61557-5(Ka pale ʻana o ka lepo); JJG 366-2004(Mika kū i ka honua) JJG 1054-2009 |