GDF-3000A DC System Earth Fault Detector
ʻO nā hewa ʻole o ka ʻōnaehana DC, nā hewa like ʻole o DC a me nā hemahema o ka mana AC he mau hewa ia e hiki mai ana a pōʻino i ka ʻōnaehana mana, a hoʻoweliweli i ka hana maʻamau o ka ʻōnaehana mana.
I mea e kōkua maikaʻi ai i nā limahana mālama kahua e ʻike wikiwiki a pololei i nā hewa DC, ua hoʻomohala kā mākou hui i kahi mea ʻimi hewa DC ma o nā makahiki o ka hoʻoikaika ʻana a me ka hōʻuluʻulu ʻana i ka nui o nā ʻike kahua.
Ke hoʻohana nei ka mea ʻimi kumu ʻāina DC i ka mīkini paʻa kiʻekiʻe o kēia manawa no ka ʻike a ʻimi ʻana i nā hewa me ka hoʻohana ʻana i ka ʻokoʻa DC o kēia manawa ma ka loop loop.Hoʻokomo ʻia ka ʻenehana hoʻololi FFT wikiwiki i loko o ka ʻenehana ʻimi hewa DC, e ʻike i nā ʻano like ʻole o ka insulation faults, DC like ʻole, a me ka mana AC i nā ʻōnaehana DC me nā pae uila like ʻole (24V (koho), 48V, 110V, 220V).
Me ka piʻi ʻana o nā koi no ka hana palekana o nā ʻōnaehana mana, e piʻi a kiʻekiʻe aʻe nā koi no nā ʻano like ʻole o ka ʻike hewa DC i nā ʻōnaehana mana.No laila, kiʻekiʻe-precision, insulation au ana e lilo i kumu koi o ka mea hana no ka mana nenoai 'hou hanauna DC huli honua.
(1) Pūnaehana-i-ground ana voltage hana, hiki i ka mea kani ke ana i ka volt system-to-ground, negative-to-ground voltage, system voltage, a hiki ke hoʻomaopopo i ka nānāʻana o ka voltage 0-300V;
(2) System insulation impedance ana hana, hiki i ka mea kani ke ana i ke kuʻekuʻe insulation o ka ʻōnaehana i ka honua, ke kū ʻole o ka insulation i ka lepo, ka ʻike ʻana i ka nui o ke alahaka kaulike, ʻo ke ana ʻana he 0-999.9KΩ;
(3) ʻO ka hana ʻike mana AC, hiki i ka mea kani ke hoʻokolokolo i ka hāʻule ʻana o ka mana AC i ka ʻōnaehana DC, a hiki ke ana i ke kumukūʻai o ka volta AC i ka ʻōnaehana DC, ʻo 0-280V ke ana ʻana o ka volta AC;
(4) Pūnaehana puʻunaue ana capacitance hana, hiki i ka mea kani ke ana i ka capacitance mahele o ka pūnaewele a hōʻike i ka manawa maoli;
(5) ʻO ka ʻike ʻana i ka ʻoihana pūnaewele a me ka hana hoʻonohonoho, hiki i ka mea kani ke ʻike i nā hewa ʻoihana apo like ʻole i nā pahu kaʻa ʻelua, me ke apo maikaʻi, ke apo maikaʻi ʻole, ke apo bipolar a me ke apo bipolar, etc. e huli i ka wahi hewa o ka pūnaewele apo;
(6) Loaʻa i ka hāmeʻa ka modulation amplitude, hoʻonohonoho hou, koho ʻana i ka nalu o kēia manawa a me ka hana koho mode hana, hiki ke ʻike i ka ʻimi a me ka wahi o nā hewa ʻoihana apo kiʻekiʻe.
(7) ʻO ke ana ʻana o ke kūpaʻa ʻana o ka lālā a me ka hana ʻana o ka insulation hewa, ke ana ka mea kani i ke kūpaʻa insulation o kēlā me kēia lālā i ka lepo, a hiki ke hoʻomaopopo i kahi o nā wahi hewa insulation ma o ka hōʻike nalu a me ka hōʻike kuhikuhi;
(8) Hoʻopau i ka hana loiloi spectrum o kēia manawa, unuhi maikaʻi ka hāmeʻa i ka amplitude hōʻailona o ka helu alapine i ana ʻia, a hoʻomaikaʻi i ka pololei ʻike ma o ka hana loiloi spectrum o ka hoʻololi o kēia manawa me ka hoʻololi FFT wikiwiki;
(9) ʻO ka hana Ammeter, hiki ke hoʻohana ʻia ka mea hana ma ke ʻano he ammeter kiʻekiʻe, a hiki i ka hoʻonā ana i kēia manawa ke hiki i 0.01mA;
(10) Hōʻike kaʻe nalu a me ka hana hōʻike kuhikuhi.I ka hoʻohana ʻana i ka mea ʻike e ʻike i ka lālā i ana ʻia, e hōʻike ia i ka hoʻololi o kēia manawa o ka lālā i ana ʻia ma ke ʻano o ka nalu nalu ma ka pale, kahi kūpono no ka mea hoʻohana e hoʻomaopopo koke i ka helu hewa.E huli i ke kuhikuhi o ka lae hewa ke loa'a ka hewa apo a me ka hewa lepo.
●Hoʻolālā hilinaʻi kiʻekiʻe
Hoʻohana ka hāmeʻa i ka microcontroller 32-bit i lawe ʻia ma ke ʻano he ʻōnaehana nui, a ʻo ka hoʻolālā hāmeʻa e hahai pono i ka mana a me ka electromagnetic compatibility standards.Hoʻohana ʻia ke ʻano redundancy kūloko e hōʻoia i ka hilinaʻi o ka hāmeʻa a me ka mea i hoʻāʻo ʻia.
●ʻO ke koho mea pono
Hoʻohana ka mea hana i ka mea hōʻiliʻili kiʻekiʻe e like me ka hōʻailona loaʻa ʻana, a ua hoʻopaʻa ʻia ka sampling volta kiʻekiʻe kiʻekiʻe i lawe ʻia mai ka chip hoʻololi analog-digital, ua ana pololei ʻia ka volta a me ka impedance;
●Hoʻopili kanaka-kamepiula pilina pili kanaka
Ke hoʻohana nei ka mea anaana a me ka mea ʻike i kahi hōʻike aniani wai TFT no nā mea hoʻohana e ʻike i ka ʻike;
He maʻalahi ka hana a me ka wikiwiki, a ke ʻike ʻia ka ʻike ʻana o nā lālā like ʻole, hiki ke hoʻopau ʻia hoʻokahi pihi hoʻomaka;
Maikaʻi nā hopena hōʻike a hiki ke hōʻike ʻia nā hopena hōʻike i ka mea hoʻohana i nā ʻano hōʻike like ʻole, me ke ʻano o ka nalu a i ʻole ka nalu, nā pae insulation, ka pale ʻana i ka insulation, ka leakage o kēia manawa, a me ka ʻike kuhikuhi.
●ʻIke naʻauao a me ka ʻōnaehana ʻike
Hoʻomaopopo 'akomi ka mea hoʻoponopono i ka pae voltage pūnaewele;
Hiki i ka mea anaana ke hoʻoholo i ke apo hewa ʻāpana;
Ma hope o ka hoʻopili ʻia ʻana o ka ʻike ʻike a me ka mea anamanaʻo i hoʻokahi manawa, ʻaʻole ia e pili i ka mamao ʻike;
Ke nānā nei ka mea ʻike, hiki i ka ʻohi ʻohi ke hoʻopaʻa i hoʻokahi kaula mana a hoʻopaʻa paha i nā kaula mana he nui e hoʻomaikaʻi i ka pono ʻike;
Ma hope o ka pau ʻana o ka hoʻāʻo detector, inā loaʻa i ka lālā i hoʻāʻo ʻia kahi kikowaena apo a i ʻole ka hewa insulation, ua hoʻoholo ʻia ka ʻike kuhikuhi o ka wahi hewa e pili ana i ka wahi hoʻāʻo.
●ʻO ka hana hoʻāʻo piha a me ka hiki ke mālama i nā hewa
Hoʻokumu ʻia ka module hoʻoili ʻikepili uea ma waena o ka mea hoʻopili a me ka mea ʻike no ke kamaʻilio.Ua piha ka hana ho'āʻo a me ka ʻike hōʻike, a hiki ke hoʻoponopono i nā ʻupena apo like ʻole a me nā hewa insulation i ka ʻōnaehana DC.
He ʻano ʻano hana like ʻole ka mea anamanaʻo ma ke koho ʻana i nā hana o "Amplitude Modulation", "Waveform" a me "Mode", hiki ke hoʻololi i nā ʻano noiʻi paʻakikī.
●Palekana kiʻekiʻe
Hoʻohana ka hāmeʻa i ka hōʻailona ʻike micro-amplitude a me ka ʻohi kiʻekiʻe kiʻekiʻe DC detection collector e ʻike i ka ʻike hewa a me ke kūlana, ʻaʻohe ona mana i ka ʻōnaehana DC.
Nā kikoʻī o ka Analyser | |
Voltage Hana | DC 22-300V. |
Ka mahana wela | -20 ℃—55 ℃ |
Ka haʻahaʻa pili | 0—90% |
ʻO ke ana uila DC | |
ʻO ke ana ʻana o ka puʻuwai DC | 22-300V |
ʻO ka hoʻonā ʻana o ke ana voli DC | 0.1V |
ʻO ka pololei o ke ana ʻana i ka volta DC | ±0.5%@ 220V DC lako mana (180V-286V) @110V DC lako mana (90V-143V) |
Ana voli AC | |
Ana AC a me DCkaulahaouila uila | 10-280v |
ʻO ka hoʻonā ana ʻana o ka volta AC | 0.1V |
ʻO ka pololei o ke ana ʻana o ka volta AC | 0.5% |
Ana kū'ē i ka insulation | |
Ka laulā ana o ka pale ʻana | 0-999.9KΩ |
ʻO ka hoʻonā ʻana i ke ʻano kūʻokoʻa | 0.1KΩ |
ʻO ke ana kūpono o ke ana kūʻokoʻa | ≤±5%Ri <10KΩhōʻikewaiwai kiko'ī 10KΩ≤Ri≤500KΩ±5% |
E ʻike i ka laulā hoʻoponopono amplitude alahaka | 0mA, 0.25mA, 0.5mA, 1mA, 2mA |
E ʻike i ka laulā kūʻē o ka pūnaewele apo | emi iho ma mua o 50KΩ |
ʻAna capacitance puʻunaue pūnaewele | |
Pūnaehana puʻunaue ana capacitance laulā | 0-999.9uFpololei C <10uF a i ʻole C>200uF: hōʻike i ka waiwai kikoʻī;10uF≤C≤200uF:±10% a i ʻole±3uF; Ke koho ʻano ʻano nalu ʻike: hawewe sine, hawewe huinahalike; |
ʻAna kūʻē honua ʻōnaehana | 0-1000kΩ |
Ke koho ʻano ʻano nalu ʻike | hawewe kine, hawewe huinahalike |
Ke ano hana | hoʻomaka hōʻailona hoʻomaka, hoʻomaka ʻakomi |
Hōʻike i ka media a me ka hoʻonā | TFT, 320x240 |
Nā kikoʻī o ka mea ʻike | |
Ana kū'ē i ka insulation | |
Ka laulā ana o ka pale ʻana | 0-500KΩ |
ʻO ka hoʻonā ʻana i ke ʻano kūʻokoʻa | 0.1KΩ |
ʻO ke ana kūpono o ke ana kūʻokoʻa | Ri <10KΩhōʻikewaiwai kiko'ī 10KΩ≤Ri≤500KΩ±10% |
Laulā kālailai spectrum | |
Ka helu o nā awāwa hoʻonaʻauao spectrum | 1 |
Laulā alapine (frequency range). | 0.125-12.5Hz |
Hoʻoholo pinepine | 0.125Hz |
Ka wā hōʻike ʻano nalu o kēia manawa | 8s; |
Hiki ke ʻike ʻia ka laulā feeder i kēia manawa | 0-2A; |
Laulā ana o kēia manawa | -100-+100mA; |
Hoʻoholo ana i kēia manawa | 0.01 mA |
Hōʻike i ka media a me ka hoʻonā | TFT, 320x240 |
Nā hōʻailona ʻenehana kamaʻilio uila | |
Laki | 2Mbps, no ka mea he pōkole loa ka manawa hoʻoili lewa, ua hoʻemi nui ʻia ka hanana collision i ka uila uila. |
Lae pinepine pinepine | 125 mau helu alapine, e hoʻokō i nā pono o ka kamaʻilio multi-point a me ka kamaʻilio hopping pinepine |
Uku-liʻiliʻi | antenna 2.4GHz i kūkulu ʻia, liʻiliʻi, 15x29mm |
Haʻahaʻa mana hoʻohana | I ka hana ʻana i ke ʻano pane, hoʻemi nui ka hoʻouna ʻana i ka ea a me ka manawa hoʻomaka |
Mea ʻimi | 1 pc |
Mea hōʻike | 1 pc |
Mea hoʻopili | 2 pcs |
Paʻi o kēia manawa | 1 pc |
Ke alakai hoao(me ke koʻi koʻikoʻi) | 1 pc |
Chihia arry | 1pc |
Mea hoʻohana's alakai | 1 pc |
Hoike Hoao Hale Hana | 1 pc |