ʻO GDWG-III SF6 Mea ʻImi Leakage Gas
GDWG-III SF6Hoʻohana nui ʻia ka ʻenehana leakage gas, me ka ʻenehana infrared non-dispersed (NDIR), e kuhikuhi a ana i ka leakage SF6 ma GIS a me ka hoʻopiha ʻana i nā lako i loko o ka ʻoihana mana.
Ana ʻia ka nui o ka leakage makahiki o nā lako uila SF6 me ke ʻano bandaging.I ka manawa like, hoʻohana nui ʻia nā mea hana i ka mana lako keʻena, substations, high voltage switch company, laboratory hood and science test.
●Mea hoʻololi uila kiʻekiʻe
●Helicopter rotor blades
●Pūnaehana hoʻoili kinoea
●Mea kinai ahi
●Haʻawina hoʻonanea ʻana
●Mea pōʻino
●pahu pahu
●ʻAʻohe pilikia radioactive.
●ʻAʻole pono e hoʻololi pinepine i ke kinoea argon maʻemaʻe kiʻekiʻe.
●ʻAʻole pono e hoʻololi i ka sensor i nā manawa a pau, ʻoi aku ka maikaʻi.
●ʻAʻole pono e hana i ka linear calibration i kēlā me kēia makahiki, ʻaʻohe ʻāpana ʻāpana.
●ʻAʻole pili ʻia e ka haʻahaʻa, ka pollution kaiapuni a i ʻole ka neʻe ʻana o ka ʻikepili.
●Ke loaʻa ka leakage nui a i ʻole SF6a hiki i ka 100% ka nui o ke kinoea, ʻaʻole ia e hoʻohaumia a poino paha.
●E ana i ka SF6leakage kinoea qualitatively a quantitatively.ʻIke i ka SF6 kinoea 3g/makahiki.
●No ka huli ʻana iā SF6wahi leakage kinoea.
●Nā ʻāpana like SF6Hōʻike ʻia ka ʻike kinoea, ka mahana, ka haʻahaʻa, ka hōʻailona mana, ka lā a me ke kūlana diaphragm pump.
●Mea hoʻohana ʻoluʻolu.
●E hoʻohana i ka ʻenehana NDIR a me ka sensor kiʻekiʻe mai Kelemānia.
●ʻO ka wikiwiki ho'āʻo wikiwiki a me ka hoʻihoʻi maikaʻi, hoʻopaʻa ʻia ka ʻikepili i loko o 10s.
●Me ka mahana a me ka uku kaomi.
●ʻAʻohe ala hoʻopunipuni, ʻaʻohe kinoea koe SF6nā pane.
●ʻO ke ana kinoea non-contact e hōʻoia ʻaʻole e ʻona ʻia ka mea ʻike ma kēlā me kēia ʻano kaila.
●ʻO ke keʻena Thermostatic e hōʻoia i ka neʻe ʻana o ka wela ma ka wela ambient no ka sensor.
●Hōʻike OLED 3.5 iniha, hiki ke heluhelu i ka lā ikaika.
●ʻO ka pākaukau lithium i kūkulu ʻia, lōʻihi ka manawa kū.
●Hoʻopilikino ʻia nā paipu e like me ke noi.
●E hōʻoia ka hoʻopaʻa ʻana o ke ala kinoea ma lalo o ka hoʻāʻo ʻana i ka hoʻoheheʻe ʻana i ka pauma.
●ʻOi aku ma mua o 100 mau pūʻulu o ka ʻikepili hoʻāʻo e mālama ʻia ma muli o ka ʻike kinoea a me ka manawa hoʻāʻo, maʻalahi ke nīnau.
●ʻO ka pahu o waho he ikaika kiʻekiʻe, pale piha, ultra-māmā ʻano mea hana ABS.
●Ana kumu: Non-dispersive infrared sensor (NDIR)
●Ana ana: 0-2000ppmv SF6
●Hoʻoholo: 0.1ppmv
●Pono: ±2%FS
ʻOi aku ka nui o ke ana ʻana ma luna o 5000ppm, ʻaʻole e pōʻino ka mea hana.
●Hapa hana hou: ≤±1%
●ʻIke: 1ppmv
●Manawa pane: ≤10s
●Ka manawa hoʻihoʻi: ≤15s
●Paʻa: ≤±20ppm, ʻoi aku ma mua o 1000hours
●ʻO ke ʻano laʻana: ʻano hoʻoheheʻe pump, kahe a hiki i 1L/min.
●Hoʻololi ʻole: ≤±1%(FS/makahiki)
●Kupa laina: ≤±1%
●Kiʻekiʻe o kēia manawa: <700mA
●Ka mana maʻamau: <2W.
●ʻO ke kaomi ea hana: 800-1150hPa.
●Ka haʻahaʻa kaiapuni: 0-95%RH
●Ka mahana mālama: -20~+60 ℃
●Hana wela: -20~+50 ℃
●Ka haʻahaʻa hana: 0-95% (non-condensing)
●Volta hana: 220VAC ± 10%, 50Hz A i ʻole i kūkulu ʻia i loko o ka pā Li, hana mau i 6 mau hola ma hope o ka uku piha.
●Ana: 220×250×120mm
●Kaumaha: ma kahi o 2kg
Huina nui | 1 hoʻonohonoho |
Luna hoʻoili | 1 apana |
Paʻa limaʻimi | 1 apana |
kāʻei kūʻē | 1 apana |
Hhe 600mm | 1 apana |
Mea hoʻohana's alakai | 1 kope |
Wkāleka hoʻonohonoho | 1 kope |