GD3128 moʻo hōʻike kūʻē kūʻē
ʻO GD3128 series Insulation Resistance Tester he hana hoʻāʻo maikaʻi loa o nā ʻāpana kūʻokoʻa insulation a me ka mana anti-interference maikaʻi loa, hiki ke hoʻohana ʻia no ka hoʻāʻo ʻana i ke kūpaʻa insulation o nā lako uila uila kiʻekiʻe kiʻekiʻe a me nā laina hoʻouna i loko o ka wahi inductive ikaika e like me substation.Hoʻohana ka mea hana i ka pale paʻi kala maoli, hōʻike ʻia nā ʻikepili hōʻike āpau a me ka mana pākaukau ma ka ʻaoʻao hoʻokahi i ka maka, a ʻo ka hui pū ʻana o ka pihi kī a me ke kī e maʻalahi loa ka hana.ʻAʻole pono ka mea hoʻohana e hoʻomanaʻo i ke ʻano hana.Kaomi iā "HELP" ma ka ʻaoʻao e hoʻopuka i ke ʻano hana, hiki ke alakaʻi pono i ka mea hoʻohana e hana i ka mea kani.Loaʻa i ka mea kani ka hana o ka hoʻokuʻu wikiwiki, hiki ke hoʻokuʻu i ka volta o ka mea i hoʻāʻo koke ʻia me ka ʻole o ka kaapuni hoʻokuʻu hou.Hiki i ka mea nānā uila ke nānā pono i ka volta ola o ka mea i hoʻāʻo ʻia.Inā ʻoi aku ka nui o ka volta ma mua o 36V, e pāpā ʻia ka hoʻāʻo, hiki ke pale pono i ka mea kani a me nā mea hana.
Hoʻohana ka mea hana i ka pā pākaukau lithium rechargeable nui.Hoʻopaʻa maʻalahi ka manawa hoʻāʻo o ka mea hana i ka manawa hoʻāʻo a mālama i nā hopena hōʻike me ka lā a me ka manawa.Hiki i ka pale paʻi ke komo maʻalahi i ka ʻikepili mōʻaukala i hoʻopaʻa ʻia.Hiki i ke kikowaena USB kaawale loa ke hoʻouka i ka ʻikepili hoʻāʻo i ka PC.Hoʻolako ʻia ka mea kani me ka laina hoʻāʻo me ka insulation pālua a me ka papa pale, a ua hoʻolako ʻia ka pahu uila kiʻekiʻe me ka pauku alligator clip a me ka makau, hiki ke hoʻololi i nā wahi hoʻāʻo like ʻole.Hoʻohana ka mea hana i kahi ʻāpana paʻa paʻa pālua, a ʻo ka māka pale o ka pahu waho he IP65, hiki ke pale i ka hoʻouka ʻana o ka lepo a me ka lepo i ka wā o ka lawe ʻana a me ka mālama ʻana, a pale pono i ka mea kani mai ka hui ʻana.
ʻO ka moʻo GD3128 he ākea ākea, hoʻonā kiʻekiʻe, hana maʻalahi, kūpaʻa a me ka lōʻihi, pololei a me ka hilinaʻi, ka hana paʻa, a me ka ikaika anti-interference.Loaʻa i ka mea hana ka ho'āʻo kū'ē kū'ē (IR);ho'āʻo polarization index (PI);hōʻike lākiō absorption (DAR);ramp test (RAMP);ho'āʻo kānana (FR, 10S, 20S, 30S, 40S ʻehā mau koho);hōʻike uila (V);hōʻike capacitance (uF);hōʻike i kēia manawa (nA) a me nā hana ʻē aʻe.Ua kūpono ka mea kani no ka hoʻāʻo ʻana i ka insulation resistance o nā mea uila, nā laina hoʻouna a me nā mea hana nui ʻē aʻe ma lalo o ke kaiapuni o ka mana nui, ka volta kiʻekiʻe a me ka induction ikaika.He mea hoʻohana maʻamau a pono ʻole ia no ka mana uila, kelepona, meteorology, lumi kamepiula, kahua ʻaila, hoʻonohonoho electromechanical a mālama, a me nā keʻena lako mana o nā ʻoihana ʻenehana a me nā ʻoihana mining.
●ʻO 7mA ka nui o ka manawa pōkole pōkole.
●ʻO ka hoʻāʻo kūʻē ʻana i ka insulation (IR), ka hoʻāʻo polarization index test (PI), absorption ratio test (DAR).
●ʻO ke ʻano hoʻāʻo Ramp (RAMP), ke ʻano hoʻāʻo kānana (FR), ka hoʻāʻo capacitance (uF)
●ʻO ka hana Voltage monitor, e nānā maʻalahi i ka volta i kau ʻia o ka mea i hoʻāʻo ʻia.
●Hana manawa ho'āʻo, hoʻopaʻa 'akomi i ka manawa ho'āʻo.
●ʻO ka hana hoʻokuʻu 'akomi, hoʻokuʻu koke a hoʻokuʻu i ka uku o ka mea hoʻāʻo ma hope o ka hoʻāʻo, me ka ʻole o kahi kaapuni hoʻokuʻu waho.
●Hana pani ʻakomi.
●Paʻi kala paʻi nui.
●ʻO ke ʻano o ka pūpū papalua, paʻa a paʻa, ka pae pale IP65.
●Kiʻekiʻe-kaha rechargeable lithium pūʻolo pila.
●ʻO ka hana mālama, hiki ke mālama i nā pūʻulu 1000 o ka ʻikepili hōʻike manawa maoli me ka lā hoʻāʻo a me ka manawa a me ka manawa hoʻāʻo.
●Hoʻouka i ka hana, hoʻolako ʻia me ka USB interface, hiki ke hoʻouka i ka ʻikepili i ka kamepiula no ka ʻikepili helu ʻikepili.
Huahana Huahana | Voltage koho | Palena Kū'ē Kū'ē | Kaapuni Pokole |
GD3128A | 250V,500V,1kV,2.5kV,5kV | 0.50MΩ~10.0TΩ | ≥7mA |
GD3128B | 250V,500V,1kV,2.5kV,5kV,10kV | 0.50MΩ~20.0TΩ | ≥7mA |
GD3128C | 250V,500V,1kV,2.5kV,5kV,10kV,15kV | 0.50MΩ~30.0TΩ | ≥7mA |
Kūlana Kūʻokoʻa a me ka pololei
Voltage koho | Huhū Kū'ē Kū'ē | Ka pololei | ʻŌlelo |
250V | 0.50MΩ~50.0GΩ | ±5%rdg±3dgt |
|
50.0GΩ~500GΩ | ±20%rdg±3dgt |
| |
500V | 1.00MΩ~100GΩ | ±5%rdg±3dgt |
|
100GΩ~1.00TΩ | ±20%rdg±3dgt |
| |
1000V | 1.00MΩ~200GΩ | ±5%rdg±3dgt |
|
200GΩ~2.00TΩ | ±20%rdg±3dgt |
| |
2500V | 1.00MΩ~500GΩ | ±5%rdg±3dgt |
|
500GΩ~3.00TΩ | ±20%rdg±3dgt |
| |
5000V | 1.00MΩ~1.00TΩ | ±5%rdg±3dgt |
|
1.00TΩ~10.0TΩ | ±20%rdg±3dgt |
| |
10KV | 1.00MΩ~2.00TΩ | ±5%rdg±3dgt |
|
2.00TΩ~20.0TΩ | ±20%rdg±3dgt |
| |
15KV | 1.00MΩ~3.00TΩ | ±5%rdg±3dgt |
|
3.00TΩ~30.0TΩ | ±20%rdg±3dgt |
1 TΩ (Tera ohm)=1000GΩ=1012Ω
1 GΩ (Giga ohm)=1000MΩ=109Ω
1 MΩ (Mega ohm)=1000KΩ=106Ω
Hana | ʻO ke ana ʻana o ke kūʻokoʻa (IR);ana helu helu polarization (PI);lākiō absorption (DAR);ʻano hoʻāʻo ramp (RAMP);kānanahana(10S, 20S, 30S, 40S);vana oltage (V);kāʻeihoʻopaʻapaʻaana ana(uF);ana i kēia manawa(nA) |
Lako ikehu | Hiki ke hoʻopaʻa hou ʻia ka pā lithium 6.2Ah |
Voltage koho | GD3128A: 250V, 500V, 1kV, 2.5kV, 5kV GD3128B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV GD3128C: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV, 15kV |
Ka pololei o ka Voltage Output | (5%~10%) ±10V |
Palekana ho'āʻo kūʻokoʻa | GD3128: 0.50MΩ~10.0TΩ GD3128B: 0.50MΩ~20.0TΩ GD3128C: 0.50MΩ~30.0TΩ |
Kaapuni Pokole Puka | ≥7mA |
Ho'āʻo Polarization Index | ʻAe |
Ho'āʻo Absorption Ratio | ʻAe |
ʻAno hoʻāʻo Ramp | E hoʻāʻo i nā ʻanuʻu o 10% o ka volta preset a hiki i ka volta preset. |
Kānana hoʻāʻo ʻano | 10S, 20S, 30S, 40S ʻehā mau koho. |
Ho'āʻo Voltage | Kaulana: AC/DC: 0V~1000V; Pono: ±5%rdg±3V |
Ho'āʻo Capacitance | Kaulana: 10nF~25uF; Pono: ±10%rdg±10nF |
Hoao o keia manawa | Kaulana: 0.01nA~7mA; Pono: ±5%rdg±0.5nA |
Nānā Voltage | E nānā i ka volta o kahoʻāʻod object, a nānā i ke kūlana hoʻokuʻu ma hope o ka hoʻāʻo ʻana, pāpā ʻia e hoʻāʻo i ka wā ma mua o 36V, pale i ka mea kani a me ka mea hoʻohana. |
Manawa hoao | Ka manawa hoʻopaʻa moʻolelo ʻakomi, timanalaulā: 0s~9999s |
Hana mālama | E mālama pono i ka ʻikepili hōʻike me ka lā a me ka manawa hoʻāʻo, ka huina o 1000 mau pūʻulu |
Hoʻouka Hana | Hoʻouka i ka ʻikepili i mālama ʻia i ke kamepiula ma o ke kaula kelepona USB. |
Hōʻike mana o ka pākaukau | Me ka hōʻike mana pākaukau, ke hoʻomanaʻo ʻia ka haʻahaʻa haʻahaʻa o ka pākaukauukuka pākaukau. |
Pani 'akomi | Ma hope o 15 mau minuke, e pani ʻia ka hoʻomaka me ka ʻole o ka hana. |
Anana | 280mm×260mm×160mm |
Kaumaha | 4900g (me ka pākaukau) |
Uea hoao | Uea ho'āʻo uila uila ʻulaʻula 1pc (mea alligator clip and hook), uea ho'āʻo kala ʻōmaʻomaʻo 1pc, uea ho'āʻo kala ʻeleʻele 1pc |
Papa Palekana | Pani i ka hihia IP65, wehe i ka hihia IP40 |
Kaiapuni Hana | -20 ℃~50 ℃; 80%rh |
Kaiapuni hale kūʻai | -25 ℃~65 ℃; 80%rh |
Kū'ē Kū'ē | 50MΩ(1000V) (ma waena o ke kaapuni hoʻāʻo a me ka pūpū) |
Kū i ka Voltage | AC 3kV50Hz 1min(ma waena o ke kaapuni hoʻāʻo a me ka pūpū) |
Palekana | IEC61010-1, IEC61326-1 |